Bunn CDBCF-MV, CDBCF-DV, CDBC APS-DV, CDBC-DV, CDBCF APS-MV Models CDBC-MV & CDBC-APS MV

Page 6

Models CDBC-MV & CDBC-APS MV

ELECTRICAL REQUIREMENTS

CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.

TANK HEATER TERMINAL BLOCK WIRING DIAGRAM

(CDBC-MV MODELS)

1800W @ 120V

1800W

1425W

 

B

B

W

 

L

L

H

 

K

U

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

WHI RED

L2 RED

 

WHITE

 

NEUTRAL

120V A.C.

 

L1 BLACK

 

1425W @ 120V

1800W

1425W

B

B

W

L

L

H

K

U

T

 

 

 

 

 

 

 

 

 

 

 

 

BLK WHI RED

L2 RED

 

WHITE

 

NEUTRAL

120V A.C.

 

L1 BLACK

 

2390W @ 120/208V

or

3180W @ 120/240V

1800W

1425W

 

B

B

W

 

L

L

H

 

K

U

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK RED

WHI

L2 RED

 

WHITE

120V A.C.

208 or

NEUTRAL

240V A.C.

120V A.C.

 

L1 BLACK

 

FIELD WIRING TERMINAL BLOCK DIAGRAM

P1888

1800W VERSION Requires 2-wire, grounded service rated 120 volts ac, 20 amp, single phase, 60 Hz.

1425W VERSION Requires 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.

2390W VERSION Requires 3-wire, grounded service rated 120/208 volts ac, 20 amp, single phase, 60 Hz.

3180W VERSION Requires 3-wire, grounded service rated 120/240 volts ac, 20 amp, single phase, 60 Hz.

ELECTRICAL HOOK-UP

CAUTION Improper electrical installation will damage electronic components. This unit is factory wired for operation on a 120 volt, 15 amp service (1425W Version).

1.An electrician must provide electrical service and verify that the tank heater connections are connected as specified in the above diagram.

2.Determine the available on-site electrical service.

3.Select the desired unit wattage based on the available on-site electrical service.

4.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

5.Remove the front panel beneath the sprayhead.

6.Feed the supply leads through the rear panel of the brewer.

7.Using the above diagrams, connect the desired electrical service to the field wiring terminal block and remove the top cover of the brewer to verify the tank heater terminal block connections.

8.The electrical service connections at the field wiring terminal block must agree with the tank heater terminal block connections as specified in the above diagram.

9.Before proceeding, verify the voltage at the field wiring terminal block. Replace the panel and top cover.

10.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing has been hooked up, the brewer is ready for Initial Set-Up.

Page 6

29707 112801

 

Image 6
Contents DIS Version Introduction TWO Warmer Brewers Three Warmer BrewersAPS Brewers No Warmer Brewers CDBCF-DV BrewersCdbc LPTC-DV Brewers ONE Warmer BrewersElectrical Requirements 1425W VersionElectrical HOOK-UP Models CDBC-MV & CDBC-APS MV Initial SET-UP CleaningPlumbing Requirements Coffee BrewingAdditional Warmer Switches ON/OFF SwitchBrew Switch Ready IndicatorDisplaying Brew Temperature Adjustments & Optional SettingsSetting Brew Temperature Setting Brew LockoutWater Sensing Threshold Adjustment Procedure Troubleshooting Before troubleshooting this brewer, check for the followingTroubleshooting Refill Circuit Problem Probable CauseRemedy Troubleshooting Refill Circuit Heating Circuit Problem Water does not heat to proper tem- peratureTank Heater Troubleshooting Heating CircuitProblem Probable Cause Ings are takenProblem Probable Cause Remedy Brewing Circuit Problem Probable Cause Dispenser Be made with sprayhead installed Troubleshooting Brewing CircuitConsistently low beverage level Brew volume Brew cycle will not start Control board or dispense valveDripping from sprayhead Lime build up Water temperatureSet-upinstructions RequiredProblem Probable Cause Diagnostics Cause Things to CheckService When servicing, except when electrical tests are reComponent Access Service Disconnect the 11-pin connector from the control panelControl Board Switch Panel Dispense Valve Limit Thermostat Wiring Limit ThermostatTank Heaters Tank Heater Terminal Block Wiring Diagram Voltage Selector Switch Terminals Refill Valve Warmer Elements Warmer ElementsFuse HOLDER/FUSE Assembly MV models only Service Thermal Fuses MV models only Thermal FusesSchematic Wiring Diagram Cdbc DV Schematic Wiring Diagram Cdbc APS-DV Cdbcf APS/TC/LPTC-DV Schematic Wiring Diagram Cdbc MV Schematic Wiring Diagram Cdbc APS MV
Related manuals
Manual 2 pages 47.58 Kb

CDBCF-MV, CDBCF APS-DV, CDBCF APS-MV, CDBC-DV, CDBC-MV specifications

The Bunn CDBCF-DV is a distinguished coffee brewer designed for commercial use, ideal for establishments that demand high-quality coffee at a fast pace. This brewer is notable for its innovative design and advanced brewing technology, making it an essential asset for cafes, restaurants, and coffee shops.

One of the standout features of the Bunn CDBCF-DV is its dual-voltage capability. This versatility allows the brewer to operate efficiently on both 120V and 240V power sources, ensuring that it meets the needs of various establishments regardless of electrical setup. This adaptability makes it a favorite among coffee vendors looking to optimize performance without the inconvenience of electrical constraints.

The BDCBF-DV also boasts a large capacity, allowing it to brew up to 14 cups of coffee in a single cycle. This is facilitated by its large water tank and high brewing rate, which can produce coffee in just a matter of minutes. The ability to brew rapidly while maintaining quality is crucial in busy environments where time is of the essence.

Key to the Bunn CDBCF-DV's performance is its patented brewing system that utilizes a pre-infusion feature. This technology ensures that the coffee grounds are saturated before the brewing process begins, promoting optimal extraction of flavors and aromas. The result is a rich, well-balanced cup of coffee that delights patrons and encourages repeat business.

Another notable characteristic is the brewer's easy-to-use control interface. With simple dial settings, baristas can effortlessly adjust brew strength and temperature, ensuring consistency with every batch. The intuitive design minimizes training time for new staff and enhances overall workflow in commercial settings.

Durability and maintenance are critical in commercial coffee brewing equipment, and the Bunn CDBCF-DV excels in this area as well. Constructed with high-quality materials, it is built to withstand the rigors of daily use. Additionally, it features easily accessible parts for straightforward cleaning and servicing, reducing downtime and ensuring that the coffee remains fresh and delicious.

In summary, the Bunn CDBCF-DV is a versatile, efficient, and user-friendly coffee brewer loaded with innovative features aimed at delivering exceptional coffee quality. Its dual-voltage operation, large capacity, pre-infusion technology, and durable design make it an indispensable choice for businesses looking to enhance their coffee offerings and improve customer satisfaction. Whether you're a small cafe or a larger restaurant chain, the Bunn CDBCF-DV is engineered to meet your coffee brewing demands with excellence.