Bunn Troubleshooting Refill Circuit, 2a. Water Level Probe Sensing System CDBC-APS/TS/TSR

Page 12
29253 111103

TROUBLESHOOTING (cont.)

REFILL CIRCUIT (cont.)

PROBLEM

Fill or refill does not shut "OFF" (ON/ OFF Switch "ON") (cont)

Fill or refill does not shut "OFF" (ON/ OFF Switch "OFF")

PROBABLE CAUSE

2a. Water Level Probe Sensing System (CDBC-APS/TS/TSR)

2b. Water Level Probe Sensing Sys- tem (CEZ-APS/TC/TS/TSR)

3.Refill valve or control board (CDBC-APS/TC/TS/TSR & CEZ- APS/TS/TSR)

4.Water is too conductive for proper operation when using the factory setting of sensing threshold. (CDBC- APS/TC/TS/TSR)

1.Refill valve or control board (CDBC-APS/TC/TS/TSR & CEZ- APS/TS/TSR)

Page 12

REMEDY

A)Disconnect the brewer from the power source. Disconnect the J3 connector from the control board. Check for continuity from the nut on top of the level probe to pin 1 of the plug, continuity should be present. Pull the temperature probe up about an inch from the grommet. Check for continuity from the outside surface of the temperature probe and pin 4 of the plug, continuity should be present. Connect the J3 plug to the control board and proceed to step 3.

B)Disconnect the brewer from the power source. Disconnect the J5 connector from the control board. Check for continuity from the nut on top of the level probe to pin 5 of the plug, continuity should be present. Pull the temperature probe up about an inch from the grom- met. Check for continuity from the outside surface of the temperature probe and pin 2 of the plug, conti- nuity should be present. Connect the J5 plug to the control board and proceed to step 3.

Press ON/OFF switch to "ON" (Indi- cator lamp should be lit). If water continuously flows out of air vent tube, disconnect the brewer from the power source. If water flow stops, replace the control board. If water flow does not stop, repair or replace the refill solenoid. (See page 30)

Reset the Water Sensing Threshold Adjustment Procedures on page 9.

If water continuously flows out of air vent tube, disconnect the brewer from the power source. If water flow does not stop, repair or replace the refill solenoid. If the valve closes when power is removed, replace the control board. (See pages 21 & 22)

Image 12
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 FAX 217Contents IntroductionUser Notices Electrical Requirements Plumbing RequirementsElectrical Hook-Up ON/OFF Switch Brew SwitchReady Indicator Operating ControlsCleaning Initial SET-UPCoffee Brewing CEZ-APS/TS/TSR Adjustments & Optional Settings Adjusting Brew VolumesCDBC-APS/TC/TS/TSR Adjustments & Optional Settings Setting Brew TemperatureDisplaying Brew Temperature Setting Brew LockoutWater Sensing Threshold Adjustment Procedure CDBC-APS/TC/TS/TSR Adjustments & Optional SettingsTroubleshooting Before troubleshooting this brewer, check for the followingTroubleshooting Refill Circuit ProblemProbable Cause RemedyTroubleshooting Refill Circuit 2a. Water Level Probe Sensing System CDBC-APS/TS/TSRHeating Circuit Problem Probable Cause Remedy Water does not heat to proper temperatureWater not touching temperature probe Troubleshooting Heating Circuit Problem Probable Cause RemedyCont Control Board Cdbc & CEZReplace the control board.See Pages 21Brewing Circuit Problem Probable Cause Troubleshooting Brewing Circuit Water temperature Set-upinstructionsDripping from sprayhead Lime build up RequiredProblem Probable Cause Dry coffee grounds remain Sprayhead FunnelFunnel loading Diagnostics Cause Things to CheckService Component AccessContents Service Control BoardService Control Board Model CEZ-APS/TS/TSR Control BoardService Switch Panel Model CDBC-APS/TC/TS/TSR Switch PanelON/OFF Switch Wiring Service Brew Switch Start Model CEZ-APS/TS/TSR Brew Switch WiringDispense Valve Dispense ValveLimit Thermostat Limit ThermostatTank Heater Tank HeaterService Tank Heater Tank Heater WiringRefill Valve Check for continuity across the refill valve coil terminals120V AC 2 Wire 120/208V AC 3 Wire 120/240V AC 3 Wire Levelsingle PhaseSchematic Wiring Diagram CEZ-APS/TS/TSR 120V AC 2 Wire Cdbc 15, 20 & 35 APS/TC/TS

CEZF, CDBC specifications

The Bunn CEZF and CDBC are two popular commercial coffee brewers offered by Bunn, a leader in the coffee equipment industry. Both models are designed to meet the demands of high-traffic settings such as cafes, restaurants, and other foodservice establishments. They combine advanced technology with user-friendly features to ensure consistent, high-quality coffee with minimal effort.

The Bunn CEZF model is known for its easy-to-use design and efficiency. One of its standout features is the "Digital Brewer" control, which allows operators to adjust brewing parameters such as brew time and water temperature. This level of customization enables baristas to consistently create the perfect cup of coffee tailored to their specific blends. Furthermore, the CEZF has a unique "intelligent" warming plate that maintains the optimal serving temperature without over-extraction, ensuring that each cup of coffee remains flavorful.

On the other hand, the Bunn CDBC incorporates a dual brewing capacity that allows for larger batches of coffee to be made simultaneously. This feature is particularly beneficial in high-demand environments where quick service is essential. The CDBC also utilizes a patented brew control technology, enabling users to select their brew strength with just a few button presses. This flexibility is complemented by its high-performance heating element, which heats water rapidly, ensuring that coffee is brewed at the ideal temperature for optimal extraction.

Both models are equipped with a large water reservoir, ensuring a continuous supply of hot water for brewing. They also feature high-quality stainless steel constructions that enhance durability and make cleaning easier. The intuitive interface on both models simplifies operation, with clear instructions that allow even novice users to brew exceptional coffee right away.

In terms of safety, both the CEZF and CDBC are designed with auto shut-off features and integrated safety protocols, minimizing the risk of overheating and ensuring a secure brewing environment.

Overall, the Bunn CEZF and CDBC are excellent choices for any commercial kitchen or café looking to serve high-quality coffee efficiently. Their advanced features, durability, and ease of use make them top contenders in the commercial brewing category.