Bunn CEZF Heating Circuit Problem Probable Cause Remedy, Water not touching temperature probe

Page 13

TROUBLESHOOTING (cont.)

HEATING CIRCUIT

PROBLEM

 

PROBABLE CAUSE

REMEDY

Water does not heat to proper temperature

IMPORTANT: Make sure no tem- perature tests are taken before the ready light is "ON". Tank tempera- ture must be stabilized before read- ings are taken.

1.Display flashing (CDBC-APS/TC/ TS/TSR) or ready light flashing (CEZ-APS/TS/TSR)

2.Water not touching temperature probe

3a. Dry Plug In Probe Sensing Sys- tem (CDBC-APS/TC/TS/TSR)

3b. Dry Plug In Probe Sensing Sys- tem (CEZ-APS/TS/TSR)

Brewer has shut down due to malfunction (See Diagnostic Chart in manual, Page 19, or under top lid).

Remove probe and grommet. Look into hole on tank lid. Water must be within one inch from top of tank.

A)Disconnect the brewer from the power source. Disconnect the J3 connector from the control board. Check for continuity from the tank mounting screw where the green wire mounts, to pin 2 of the plug, continuity should be present. Pull the temperature probe up about an inch from the grommet. Check for continuity from the outside surface of the temperature probe and pin 4 of the plug, continuity should be present. Connect the J3 plug to the control board and proceed to step 4a.

B)Disconnect the brewer from the power source. Disconnect the J5 connector from the control board. Check for continuity from the tank mounting screw where the green wire mounts, to pin 4 of the plug, continuity should be present. Pull the temperature probe up about an inch from the grommet. Check for continuity from the outside surface of the temperature probe and pin 2 of the plug, continuity should be present. Connect the J5 plug to the control board and proceed to step 4b.

Page 13

29253 111103

 

Image 13
Contents Phone 217 FAX 217 Post Office BOX SPRINGFIELD, IllinoisIntroduction ContentsUser Notices Plumbing Requirements Electrical RequirementsElectrical Hook-Up Brew Switch ON/OFF SwitchReady Indicator Operating ControlsInitial SET-UP CleaningCoffee Brewing Adjusting Brew Volumes CEZ-APS/TS/TSR Adjustments & Optional SettingsSetting Brew Temperature CDBC-APS/TC/TS/TSR Adjustments & Optional SettingsDisplaying Brew Temperature Setting Brew LockoutCDBC-APS/TC/TS/TSR Adjustments & Optional Settings Water Sensing Threshold Adjustment ProcedureBefore troubleshooting this brewer, check for the following TroubleshootingRefill Circuit Problem TroubleshootingProbable Cause Remedy2a. Water Level Probe Sensing System CDBC-APS/TS/TSR Troubleshooting Refill CircuitWater does not heat to proper temperature Heating Circuit Problem Probable Cause RemedyWater not touching temperature probe Problem Probable Cause Remedy Troubleshooting Heating CircuitControl Board Cdbc & CEZ ContReplace the control board.See Pages 21Brewing Circuit Problem Probable Cause Troubleshooting Brewing Circuit Set-upinstructions Water temperatureDripping from sprayhead Lime build up RequiredDry coffee grounds remain Sprayhead Funnel Problem Probable CauseFunnel loading Cause Things to Check DiagnosticsComponent Access ServiceContents Control Board ServiceControl Board Service Control Board Model CEZ-APS/TS/TSRSwitch Panel Service Switch Panel Model CDBC-APS/TC/TS/TSRON/OFF Switch Wiring Brew Switch Wiring Service Brew Switch Start Model CEZ-APS/TS/TSRDispense Valve Dispense ValveLimit Thermostat Limit ThermostatTank Heater Tank HeaterTank Heater Wiring Service Tank HeaterCheck for continuity across the refill valve coil terminals Refill ValveLevelsingle Phase 120V AC 2 Wire 120/208V AC 3 Wire 120/240V AC 3 WireSchematic Wiring Diagram CEZ-APS/TS/TSR Cdbc 15, 20 & 35 APS/TC/TS 120V AC 2 Wire

CEZF, CDBC specifications

The Bunn CEZF and CDBC are two popular commercial coffee brewers offered by Bunn, a leader in the coffee equipment industry. Both models are designed to meet the demands of high-traffic settings such as cafes, restaurants, and other foodservice establishments. They combine advanced technology with user-friendly features to ensure consistent, high-quality coffee with minimal effort.

The Bunn CEZF model is known for its easy-to-use design and efficiency. One of its standout features is the "Digital Brewer" control, which allows operators to adjust brewing parameters such as brew time and water temperature. This level of customization enables baristas to consistently create the perfect cup of coffee tailored to their specific blends. Furthermore, the CEZF has a unique "intelligent" warming plate that maintains the optimal serving temperature without over-extraction, ensuring that each cup of coffee remains flavorful.

On the other hand, the Bunn CDBC incorporates a dual brewing capacity that allows for larger batches of coffee to be made simultaneously. This feature is particularly beneficial in high-demand environments where quick service is essential. The CDBC also utilizes a patented brew control technology, enabling users to select their brew strength with just a few button presses. This flexibility is complemented by its high-performance heating element, which heats water rapidly, ensuring that coffee is brewed at the ideal temperature for optimal extraction.

Both models are equipped with a large water reservoir, ensuring a continuous supply of hot water for brewing. They also feature high-quality stainless steel constructions that enhance durability and make cleaning easier. The intuitive interface on both models simplifies operation, with clear instructions that allow even novice users to brew exceptional coffee right away.

In terms of safety, both the CEZF and CDBC are designed with auto shut-off features and integrated safety protocols, minimizing the risk of overheating and ensuring a secure brewing environment.

Overall, the Bunn CEZF and CDBC are excellent choices for any commercial kitchen or café looking to serve high-quality coffee efficiently. Their advanced features, durability, and ease of use make them top contenders in the commercial brewing category.