Cecilware GB1P, GB2P Drink Strength Adjustments, Units With Fixed Speed Auger Motors-AC CD175

Page 5

HOPPER COVER CD106

AUGER GEAR – FOR RECTANGULAR HOPPERS:

CD117 [Used With Nylon Auger CD130]

CD117 [Used With Wire Auger CD101 &CD130]

FRONT BUSHING:

Rectangular Hoppers:

CD277 [ Ø22.5 mm ]

CD306 [ Ø17 mm ]

Square Hoppers:

CD102 [ Ø22.5 mm w/O-Ring CD103]

CD131 [ Ø22.5 mm w/O Ring]

AUGERS:

CD130 Nylon Auger [Ø22.5 mm X 17mm Pitch w/O-Ring CD139] CD101 Wire Auger [Ø22.5 mm X 17mm Pitch]

Used for Cappuccino Fast Flow & Soup.

PRODUCT GUIDE: CD70A

DISPENSE CAP: [CD61A White, CD272 Black]

MIXING CHAMBER, FAST FLOW:

[CD137 White, CD275 Black]

Correct Water Level, For Max. Flow Rate, when using Nylon Auger [Adjust Water Flow Rate so that the water level reaches almost to the top in the Mixing Chamber]

Correct Water Level, For Max. Flow Rate, when using Wire Auger [Adjust Water Flow Rate so that the water level reaches Half Way Up in the Mixing Chamber]

DISPENSE NOZZLE: CD67A White

DRINK STRENGTH ADJUSTMENTS

Nut CD136 Turn CW to unscrew

Triangular

Rib

A. Units With Fixed Speed Auger Motors-AC [CD175]

Fixed Auger Speed [95 RPM] and dispenses powder at a constant fixed rate.

Drink Strength adjustments can be made by adjusting the water flow rate on the Water Dispense Valves. [See section VI]

1.Remove side panel to access the Dispense Valve.

2.Locate Flow Adjustment Screw on Dispense Valve. [See section VI]

3.Rotate adjustment screw Counterclockwise to INCREASE Flow Rate, Clockwise to DECREASE Flow Rate.

(Note: the water flow rate should not exceed 1 to 1.3 oz./sec.)

Do not turn Adjustment Key more than 1/4 turn at a time without checking drink strength (ratio of water to powder).

B. Units With Variable Speed Auger Motors-DC [CD151] - (OPTIONAL FEATURE)

Variable Auger Speed [10 to 130 RPM]

Drink or Product Strength adjustments can be made by adjusting the Auger Motor speed. The Knobs on inside door panel control the amount of product being dispensed [gram throw]. The gram throw is factory preset at 7. Because the consistency of each product varies, the customer can set the desired gram throw for each hopper.

The water flow rate on the Dispense Valves should remain fixed.

Note: the water flow rate should not exceed 1-1.3 oz./sec to avoid spillage from dispense chamber. [See section VI]

5

Image 5
Contents CAPPUCCINO, COFFEE, and Soup Dispensers GB Pourover models Mechanical Specifications See illustration 9-3 for clarification Start UP Instructions for GB Pourover Cappuccino DispenserNormal Operation Pourover and Autorefill Units With Fixed Speed Auger Motors-AC CD175 Drink Strength AdjustmentsDrink Size Adjustments Optional Feature Test Hi-Level Float Switch TestWater Inlet Valve Test Probe TestProblem Probable Cause Remedy Troubleshooting Guide for GB-POUROVERTo Replace The Starter MaintenanceCleaning Cleaning and SanitizingQ174Q Reservoir Assembly QTY Description Reservoir and Tank AssemblyDescription and Location of Components GB3P Shown Description GB1P GB2P GB3P Door Unit Door Unit Main Unit Door Unit Door Unit Main Unit Door Unit Main Unit