Quantum Scale System

Adjusting the Scale Feet

There are four (4) Scale Feet located underneath the scale

 

system. You may need to adjust these feet slightly in the

 

 

event the scale isn’t sitting on the table/case properly.

 

Proper adjustment of these feet, helps you maintain the

 

proper scale balance.

To check scale balance:

1.Remove the Scale Platter.

2.Locate the Level on the Scale Sub-Platter. It can be seen through a hole in the scale main housing.

3.Adjust the feet until the “bubble” is in the middle of the level.

To increase the length of the scale feet:

1.Rotate the feet in the counterclockwise direction.

2.Rotate the lock nut until it is firmly against the scale base housing to lock the adjustment into place.

To decrease the length of the scale feet:

1.Rotate the feet in the clockwise direction.

2.Rotate the lock nut until it is firmly against the scale base housing to lock the adjustment into place.

2 - 15

General Information

Page 25
Image 25
Hobart ML-29048, ML-29191, ML-29044, ML-29188, ML-29039, ML-29035, ML-29037 Adjusting the Scale Feet, To check scale balance