Quantum Scale System
Production Entry Mode
☛Note
From a Flashkey Screen, PRESS [HELP] to access the On Screen Library.
This mode enables you to enter several fixed weight PLU’s and the number of labels you want to print for each. For example, Production Entry allows you to print 100 bread labels and 50 cupcake labels with one operation.
✎Tip
Processing Fixed Weight PLU’s Only
QUICK STEPS
From the Start a Run Screen:
1.Enter your Operator ID
2.Enter the PLU Number
3.TYPE No. of Labels
4.PRESS [▲]
5.Enter the PLU Number
6.TYPE No. of Labels
7.Repeat Steps 5 & 6 as needed
8.PRESS [PRINT]
You may want to setup your scale to stream labels (print labels without removing the backing paper from the label). Refer to Streaming
For Fixed Weight PLU’s only:
1.Enter your Operator ID (if required).
2.Enter the PLU number (Select Flashkey, Type PLU number or select from the On Screen Library).
3.TYPE the number of labels required in the Enter Label Count block.
4.PRESS the UP ARROW (▲) key to move to the Product Number block.
5.Enter the next PLU number (Select Flashkey, Type PLU number or select from the On Screen Library).
6.TYPE the number of labels required in the Enter Label Count block.
7.Repeat Steps 4 - 6 as needed.
8.When the last PLU has been entered, PRESS [PRINT] to begin the label run.
9.At the end of the run, the scale automatically returns to the Start a Run Screen.
6 - 7 | Weigh Types (Modes of Operation) |