Quantum Scale System
Verify Fixed Weight Mode
Processing Fixed Weight PLU’s
QUICK STEPS
From the Start a Run Screen:
1.Enter your Operator ID
2.Enter a PLU Number
3.Type No. of Labels
4.PRESS [PRINT]
5.Place package on scale
6.Place label on package
7.PRESS [ESC]
Processing Random Weight & By Count PLU’s
☛Note
Fixed Weight products or items sold By Count do not require weight on the platter to print a label.
From this mode, you can verify that a package weight is greater than or equal to the product’s fixed weight. If the package does not weigh enough, a prompt alerts you and no label is printed.
For Fixed Weight PLU’s:
1.Enter your Operator ID (if required).
2.Enter the PLU number (Select Flashkey, Type PLU number or select from the On Screen Library).
3.TYPE the number of labels desired in the Enter Label Count box.
4.PRESS [ENTER].
5.Place the package on the platter for weighing.
6.If the package does not meet the minimum weight requirements, remove the package.
7.Place another package on the platter for weighing.
8.When the package meets the weight requirements, a label will automatically be generated. After the number of labels requested finish printing, the scale returns to the Flashkey Screen (if configured) or clears the PLU field and remains on the Run Screen.
9.PRESS [ESC] to return to the Start a Run Screen.
For Random Weight or By Count PLU’s:
1.Enter your Operator ID (if required).
2.Enter the PLU number (Select Flashkey, Type PLU number or select from the On Screen Library).
3.Place the product on the platter for weighing. A label is automatically generated. The scale remains on the Run Screen, allowing you to weigh additional packages with the same or different PLU.
4.PRESS [ESC] to return to the Flashkey Screen (if configured) or the Start a Run Screen.
☛Note
Fluid Ounce PLU’s cannot be verified in the Fixed Weight Verify Mode. However, you can print a label for the item.
Weigh Types (Modes of Operation) | 6 - 12 |