Electrical Specifications

 

 

 

 

 

 

 

 

Number of

 

Receptacle

Circuit

Model No.

Volts

Phase

Hz

Watts

Heaters

Amps

Nema No.

Breaker

GB1P, GB2P, GB3P

120V

1

60

1.8KW

1

15

5-15R

15A

GB4P

 

 

 

 

 

 

 

 

GB1P, GB2P, GB3P,

120/240V

1

50/60

3.0KW

1

15

L14-20R**

20A

GB4P

or

 

 

 

 

 

 

 

 

240V

 

50/60

3.0KW

 

15

L6-20R

20A

120V, 1.8 KW, 15A, Nema 5-15R standard on all models; 3.0 KW, 120/240V units available

** 120/240V, 3 pole, 4 wire grounding type Twist-Plug Receptacle.

For 240V units, Use L6-20R, 2 pole, 3 Wire Twist-Plug Receptacle.

For Wiring, refer to Wiring Diagrams.

See Electrical Data Label attached to the back of the unit for proper voltages, breaker sizes and electrical outlet requirements for each model number listed.

Mechanical Specifications

Model #

No. of

Hopper

 

Width

Dept

Hight

Tank

Burst

Lit Display Area

Ship

 

Hoppers

Capacity

 

(in.)

(in.)

(in.)

(gal.)

Capacity

(W x H) sq. in

Weight

 

 

(lb.)

 

 

 

 

 

 

 

(lb.)

GB1P-LD

1

4 lb.

 

8.5

22

31.5

1.5

15

(7X13) 91

70

GB2P-LD

2

4 lb.

 

8.5

22

31.5

1.5

15

(7X13) 91

75

GB3P-LD

3

4 lb.

 

11

22

31.5

2

22

(9.5X13) 123.5

90

GB4P-LD

4

4 lb.

 

14.125

22

31.5

4.5

45

(12.375X13) 123.5

100

Hight: Add

an additional 4” when

installing

with

4” legs.

 

 

 

 

Add an additional 14” min

for water bottle and additional height space to invert bottle over the top.

* Burst Capacities - Max. number of drinks dispensable with available hot water - based on 6 oz. cups. ** Add 2" for line cord and valve fitting clearance.

Plumbing: ¼” water line required.

2

Image 2
Contents CAPPUCCINO, COFFEE, and Soup Dispensers GB Pourover models Mechanical Specifications Start UP Instructions for GB Pourover Cappuccino Dispenser See illustration 9-3 for clarificationNormal Operation Pourover and Autorefill Drink Strength Adjustments Units With Fixed Speed Auger Motors-AC CD175Drink Size Adjustments Optional Feature Water Inlet Valve Test Hi-Level Float Switch TestTest Probe TestTroubleshooting Guide for GB-POUROVER Problem Probable Cause RemedyMaintenance To Replace The StarterCleaning and Sanitizing CleaningReservoir and Tank Assembly Q174Q Reservoir Assembly QTY DescriptionDescription and Location of Components GB3P Shown Description GB1P GB2P GB3P Door Unit Door Unit Main Unit Door Unit Door Unit Main Unit Door Unit Main Unit