To Replace The Picture / Duratran GB w/ Metal Doors Only: Lift up the two end tabs on top of door with a pointed object

or flat head screwdriver.

Pull the entire picture frame out. Open up the two clear panels and replace picture.

Tuck clear plastic panel inside bracket at top.

Be sure to tuck clear panel under bracket before sliding frame ass'y inside door. The longer metal tab side goes in the front.

To Replace The Fluorescent Bulb:

Remove the upper inside door panel. Turn the lamp and pull it out of the lamp holder, then place the new lamp into the lamp holder and turn it until it snaps into position.

To Replace The Starter:

Remove the upper inside door panel, turn the starter slightly counter-clockwise and take it out of the starter base. To install the new starter, snap the starter into the starter base and turn it slightly clockwise into position.

RECOMMENDED PREVENTIVE MAINTENANCE

1.Check All Chamber Mounts For Signs Of Wear A. Product Running Down The Front Of The Unit.

B. Product Built Up On The Back Of Chamber Mount. Remove Chamber Mount.

Clean And Re-Lubricate Motor Shaft Using Food Grade Lubricant Only Replace With New Chamber Mount.

2.Clean Out Vent Motor, Trough And Tubing. Lift up black tabs, remove Trough Drawer, Clean, and replace Trough Drawer.

Remove Hose Assembly From The Motor. Clean Out And Replace.

3)Check All Dispense Valves For Lime Build-Up. Drain The Water Tank To Just Below The Level Of The Dispense Valves.

Remove The Valves And Clean.

( You Can Take These Valves Apart By Hand As Shown). Replace The Assembly As Needed (L467A).

Replace The Valve Into The Tank And Refill tank.

9

DURATRAN

FRAME ASS'Y

DURATRAN

BULB TYPE

F8T5/CW

LAMP HOLDER

STARTER TYPE FS-5

STARTER BASE

BALLAST

WATER FLOW ADJUSTMENT

Image 9
Contents CAPPUCCINO, COFFEE, and Soup Dispensers GB Pourover models Mechanical Specifications See illustration 9-3 for clarification Start UP Instructions for GB Pourover Cappuccino DispenserNormal Operation Pourover and Autorefill Units With Fixed Speed Auger Motors-AC CD175 Drink Strength AdjustmentsDrink Size Adjustments Optional Feature Test Hi-Level Float Switch TestWater Inlet Valve Test Probe TestProblem Probable Cause Remedy Troubleshooting Guide for GB-POUROVERTo Replace The Starter MaintenanceCleaning Cleaning and SanitizingQ174Q Reservoir Assembly QTY Description Reservoir and Tank AssemblyDescription and Location of Components GB3P Shown Description GB1P GB2P GB3P Door Unit Door Unit Main Unit Door Unit Door Unit Main Unit Door Unit Main Unit