Cecilware GB2P, GB1P, GB4P Troubleshooting Guide for GB-POUROVER, Problem Probable Cause Remedy

Page 8

TROUBLESHOOTING GUIDE FOR GB-POUROVER

WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact.

 

PROBLEM

 

 

 

PROBABLE CAUSE

 

 

REMEDY

 

 

1

 

A

 

Dispensing unit unplugged

 

 

 

Reconnect dispensing unit

 

 

Light Display

 

B

 

No power from Terminal Block

 

 

 

Check the Terminal Block for loose wire

 

 

not lit.

 

C

 

Defective Bulb

 

 

Replace Bulb.

 

 

No power.

 

 

 

 

 

 

 

 

 

D

 

Defective Ballast.

 

 

Replace Ballast.

 

 

 

 

E

 

Loose Bulb in socket.

 

 

 

Make sure bulb is seated properly in socket.

 

2

 

A

 

Water supply OFF.

 

 

Turn water ON.

 

 

No water

 

B

 

Clogged inlet screen (Water Inlet Valve).

Disconnect water line and clean inlet screen.

 

 

when Rinse

 

 

 

 

 

 

 

 

 

 

C

 

Inoperative Water Inlet Valve.

 

 

Check connection, if needed replace Valve.

 

 

Switch is ON.

 

 

 

 

 

 

Check all electrical connections.

 

 

 

D

 

Loose electrical connection.

 

 

 

 

3

 

A

 

No product in Hopper.

 

 

 

Add product.

 

 

No product

 

B

 

Auger not working.

 

 

 

Engage Hopper/Nut to Motor Gear (See section VI).

 

 

when

 

C

 

Damaged, loose, or missing Agitator

 

 

Replace Agitator/Auger Gear (See section VI).

 

 

Dispense

 

 

 

Gear.

 

 

 

 

 

Button is

 

D

 

Inoperative Auger Motor or Relay.

 

 

Check connections of Motor, Relay and/or Switch,

 

 

pressed

 

 

 

 

 

 

 

if needed replace components.

 

 

 

 

E

 

Hopper outlet clogged

 

 

Clean Hopper and check Cartridge Heater.

 

 

 

 

F

 

Faulty Coupling.

 

 

 

Replace damaged Coupling components.

 

 

4

 

A

 

Leaking Water Inlet Valve.

 

 

Clean/check fittings of Water Inlet Valve. Replace

 

 

Water does

 

 

 

 

 

 

 

Water Inlet Valve if needed. See ”Water Inlet Valve

 

 

not shut off.

 

 

 

 

 

 

 

Test”

 

 

Water keeps

 

B

 

Inoperative Dispense Switch

 

 

Check Switch connections.

 

 

dispensing.

 

 

 

 

 

 

 

Replace Dispense Switch if needed.

 

 

 

 

C

 

Inoperative Rinse Switch

 

 

Check Rinse Switch connections.

 

 

 

 

 

 

 

 

 

 

Replace Rinse Switch if inoperative.

 

 

 

 

D

 

Clogged/stuck Water Dispense Valve

 

 

Clean or unclog Water Dispense Valve.

 

 

 

 

 

 

 

 

 

 

Replace Dispense Valve if inoperative.

 

 

5

 

A

 

Heater Switch is OFF.

 

 

 

Turn Heater Switch ON.

 

 

Water is not

 

B

 

Thermostat is OFF.

 

 

 

Turn Thermostat ON. Turn Knob Clockwise.

 

 

heating up in

 

C

 

Loose connection on Thermostat.

 

 

Make sure all wires and terminals on Thermostat are

 

 

the HOT

 

 

 

 

 

 

 

tight.

 

 

water tank.

 

D

 

Hi-Limit Temperature Switch is defective

 

Replace the Hi-limit.

 

 

 

 

E

 

Heater is burned out or defective.

 

 

 

Replace the Heater.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Image 8
Contents CAPPUCCINO, COFFEE, and Soup Dispensers GB Pourover models Mechanical Specifications Start UP Instructions for GB Pourover Cappuccino Dispenser See illustration 9-3 for clarificationNormal Operation Pourover and Autorefill Drink Strength Adjustments Units With Fixed Speed Auger Motors-AC CD175Drink Size Adjustments Optional Feature Hi-Level Float Switch Test TestWater Inlet Valve Test Probe TestTroubleshooting Guide for GB-POUROVER Problem Probable Cause RemedyMaintenance To Replace The StarterCleaning and Sanitizing CleaningReservoir and Tank Assembly Q174Q Reservoir Assembly QTY DescriptionDescription and Location of Components GB3P Shown Description GB1P GB2P GB3P Door Unit Door Unit Main Unit Door Unit Door Unit Main Unit Door Unit Main Unit