Bard QC501 Installation Instructions, Mounting the Unit, Removing Locking Screws from Wheels

Page 16

INSTALLATION INSTRUCTIONS

MOUNTING THE UNIT

When installing a QC unit near an interior wall on the left side, a minimum of 8 inches is required; 12 inches is preferred.

When installing a QC unit near an interior wall on the right side, a minimum of 12 inches is required as additional space is required to connect the drain.

This clearance is required to allow for the attachment of the unit to the wall mounting brackets and the side trim pieces to the wall.

This unit is to be secured to the wall with the wall mounting brackets provided. The unit itself, the supply duct, and the free blow plenum are suitable for “0” clearance to combustible material.

NOTE: When a wall sleeve is to be used discard the brackets shipped with the heat pump and attache the unit to the sleeve with bracket supplied with the wall sleeve.

Following are the steps for mounting the QC units for reference see Figure 13.

7.Position side trim pieces to the wall and attach with field supplied screws. There are two long and two short pieces supplied. The long pieces are to enclose the gap behind the unit. The short pieces are to fill the gap behind the cabinet extension or the free blow plenum box. They may be cut to suit the ceiling height or overlap the unit side trim. There is sufficient length to trim up to a 10’2” ceiling.

FIGURE 12

REMOVING LOCKING SCREWS FROM WHEELS

1.Attach wall mounting bracket to the structure wall with field supplied lag bolts. The fluid piping connections are to be within the confines of this bracket. See Figure 1 for cabinet openings and location of fluid coil connection points.

2.Position the unit in front of the wall mounting bracket.

3.Remove the locking screws from the wheels. Refer to Figure 11.

4.Roll the unit up to the wall mounting bracket. The unit must be level from side to side. If any adjustments are necessary, shim up under the rollers with sheets of steel or any substance that is not affected by moisture.

5.Secure the unit to the wall bracket with provided #10 hex head sheet metal screws. There are prepunched holes in the cabinet sides, and the bracket has slotted holes to allow for some misalignment.

6.Position the bottom trim piece to the unit and attach with provided screws (dark colored).

REMOVE SCREWS FROM WHEELS

BEFORE ROLLING INTO PLACE

MIS-1523

Manual 2100-416 Page 14

Image 16
Contents QC Series Installation Chilled Water Unit Instructions Model QC501Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersElectrical Specifications QC Series Water Source General InformationQC Model Nomenclature Factory BUILT-IN Electric Heat TableCooling Performance Chart PsigUnit Dimensions Unit Removal from Skid Shipping DamageHandling Unit After Removal from Skid Minimum Installation Height Removal of Wall Bracket from Shipping LocationGeneral Proper Handling of Unit After Removal from SkidInstallation of Unit Thru Wall with Wall Sleeve Installation with Free Blow Plenum Ducted ApplicationDuct Work FiltersSupply Duct Connections Filter LocationCondensate Drain Side Drain Side ViewRear Drain TOP View Optional Rear DrainBarometric Fresh AIR Damper Optional Commercial Room Ventilator OptionFresh AIR Damper Removal Qtec Energy Recovery Ventilator Option Removal of the Qtec Energy Recovery VentilatorMounting the Unit Installation InstructionsRemoving Locking Screws from Wheels Side Trim Pieces Wall Mounting Bracket Wiring Main Power Component LocationWiring LOW Voltage Wiring Fluid ConnectionsOperating Voltage Range Wall Thermostats and Subbase CombinationsLOW Voltage Connections Blower Motor LOW Voltage Wire Harness PlugLOW Voltage Connections for DDC Control Remote Thermostat Wiring Diagram Option Remote Thermostat Wiring Diagram Thermostat Option Important Installer Note Service HintsStart UP Optional CFMTroubleshooting ECM Blower Motors SymptomSymptom Valve Detail Internal 2-WAY Valve PipingInternal 3-WAY Valve Piping

QC501 specifications

The Bard QC501 is an innovative piece of equipment designed specifically for quality control in various manufacturing processes. Known for its precision and efficiency, the QC501 serves multiple industrial sectors, including pharmaceuticals, food and beverage, cosmetics, and chemical manufacturing.

One of the standout features of the Bard QC501 is its state-of-the-art measurement technology. It utilizes advanced sensors and automated systems to ensure highly accurate readings. This precision is critical for industries where even the smallest deviation can result in significant issues, such as compromised product safety or regulatory violations.

The QC501 incorporates a user-friendly interface that simplifies operation for technicians and quality control personnel. Its touchscreen display provides real-time data, allowing users to monitor processes effectively and make on-the-fly adjustments as needed. This responsiveness ensures that production standards are consistently met, enhancing overall efficiency.

Another notable characteristic of the Bard QC501 is its data logging capabilities. The device is equipped with comprehensive software that records, analyzes, and generates reports on quality metrics. This feature is invaluable for facilitating thorough audits and maintaining compliance with stringent industry regulations. By providing a digital trail of quality data, the QC501 empowers companies to demonstrate their commitment to quality assurance.

In terms of connectivity, the QC501 is designed to integrate seamlessly into existing production lines. It offers multiple connectivity options, such as Ethernet and USB ports, making it compatible with various systems. This flexibility allows businesses to enhance their existing quality control processes without a complete overhaul of their infrastructure.

Durability is another critical aspect of the QC501. Manufactured with robust materials, it is designed to withstand the rigors of industrial environments. This reliability reduces downtime due to equipment failure, ensuring that production schedules remain on track.

In summary, the Bard QC501 stands out for its precision measurement technology, user-friendly interface, comprehensive data logging, seamless connectivity, and rugged durability. This combination of features makes it an essential tool for industries striving to maintain high quality standards while optimizing production efficiency. Investing in the Bard QC501 is a proactive step toward enhancing overall product quality and ensuring compliance with regulatory standards.