Bard QC501 installation instructions Getting Other Information and Publications

Page 3

GETTING OTHER INFORMATION AND PUBLICATIONS

These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard.

National Electrical Code

ANSI/NFPA 70

Standard for the Installation

ANSI/NFPA 90A

of Air Conditioning and

 

 

Ventilating Systems

 

 

Standard for Warm Air

ANSI/NFPA 90B

Heating and Air

 

 

Conditioning Systems

 

 

Load Calculation for Residential

ACCA Manual J

Winter and Summer

 

 

Air Conditioning

 

 

Duct Design for Residential

ACCA Manual D

Winter and Summer Air Conditioning

 

and Equipment Selection

 

 

Closed-Loop/Ground Source Heat Pump

IGSHPA

Systems Installation Guide

 

 

Grouting Procedures for Ground-Source

IGSHPA

Heat Pump Systems

 

 

Soil and Rock Classification for the Design ... IGSHPA of Ground-Coupled Heat Pump Systems

Ground Source Installation Standards

IGSHPA

Closed-Loop Geothermal Systems – Slinky ... IGSHPA Installation Guide

FOR MORE INFORMATION, CONTACT THESE PUBLISHERS:

ACCA

Air Conditioning Contractors of America

 

1712 New Hampshire Avenue

 

Washington, DC 20009

 

Telephone: (202) 483-9370

 

Fax: (202) 234-4721

ANSI

American National Standards Institute

 

11 West Street, 13th Floor

 

New York, NY 10036

 

Telephone: (212) 642-4900

 

Fax: (212) 302-1286

ASHRAE American Society of Heating Refrigerating, and Air Conditioning Engineers, Inc.

1791 Tullie Circle, N.E.

Atlanta, GA 30329-2305

Telephone: (404) 636-8400

Fax: (404) 321-5478

NFPA

National Fire Protection Association

 

Batterymarch Park

 

P.O. Box 9101

 

Quincy, MA 02269-9901

 

Telephone: (800) 344-3555

 

Fax: (617) 984-7057

IGSHPA International Ground Source

Heat Pump Association

490 Cordell South

Stillwater, OK 74078-8018

Manual 2100-416 Page 1

Image 3
Contents Model QC501 QC Series Installation Chilled Water Unit InstructionsContents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsFactory BUILT-IN Electric Heat Table Electrical SpecificationsQC Series Water Source General Information QC Model NomenclaturePsig Cooling Performance ChartUnit Dimensions Shipping Damage Unit Removal from SkidHandling Unit After Removal from Skid Proper Handling of Unit After Removal from Skid Minimum Installation HeightRemoval of Wall Bracket from Shipping Location GeneralInstallation of Unit Thru Wall with Wall Sleeve Ducted Application Installation with Free Blow PlenumFilter Location Duct WorkFilters Supply Duct ConnectionsOptional Rear Drain Condensate DrainSide Drain Side View Rear Drain TOP ViewCommercial Room Ventilator Option Barometric Fresh AIR Damper OptionalFresh AIR Damper Removal Removal of the Qtec Energy Recovery Ventilator Qtec Energy Recovery Ventilator OptionInstallation Instructions Mounting the UnitRemoving Locking Screws from Wheels Side Trim Pieces Wall Mounting Bracket Component Location Wiring Main PowerWall Thermostats and Subbase Combinations Wiring LOW Voltage WiringFluid Connections Operating Voltage RangeBlower Motor LOW Voltage Wire Harness Plug LOW Voltage ConnectionsLOW Voltage Connections for DDC Control Remote Thermostat Wiring Diagram Option Remote Thermostat Wiring Diagram Thermostat Option Optional CFM Important Installer NoteService Hints Start UPSymptom Troubleshooting ECM Blower MotorsSymptom Internal 2-WAY Valve Piping Valve DetailInternal 3-WAY Valve Piping

QC501 specifications

The Bard QC501 is an innovative piece of equipment designed specifically for quality control in various manufacturing processes. Known for its precision and efficiency, the QC501 serves multiple industrial sectors, including pharmaceuticals, food and beverage, cosmetics, and chemical manufacturing.

One of the standout features of the Bard QC501 is its state-of-the-art measurement technology. It utilizes advanced sensors and automated systems to ensure highly accurate readings. This precision is critical for industries where even the smallest deviation can result in significant issues, such as compromised product safety or regulatory violations.

The QC501 incorporates a user-friendly interface that simplifies operation for technicians and quality control personnel. Its touchscreen display provides real-time data, allowing users to monitor processes effectively and make on-the-fly adjustments as needed. This responsiveness ensures that production standards are consistently met, enhancing overall efficiency.

Another notable characteristic of the Bard QC501 is its data logging capabilities. The device is equipped with comprehensive software that records, analyzes, and generates reports on quality metrics. This feature is invaluable for facilitating thorough audits and maintaining compliance with stringent industry regulations. By providing a digital trail of quality data, the QC501 empowers companies to demonstrate their commitment to quality assurance.

In terms of connectivity, the QC501 is designed to integrate seamlessly into existing production lines. It offers multiple connectivity options, such as Ethernet and USB ports, making it compatible with various systems. This flexibility allows businesses to enhance their existing quality control processes without a complete overhaul of their infrastructure.

Durability is another critical aspect of the QC501. Manufactured with robust materials, it is designed to withstand the rigors of industrial environments. This reliability reduces downtime due to equipment failure, ensuring that production schedules remain on track.

In summary, the Bard QC501 stands out for its precision measurement technology, user-friendly interface, comprehensive data logging, seamless connectivity, and rugged durability. This combination of features makes it an essential tool for industries striving to maintain high quality standards while optimizing production efficiency. Investing in the Bard QC501 is a proactive step toward enhancing overall product quality and ensuring compliance with regulatory standards.