Bard QC501 Shipping Damage, Unit Removal from Skid, Handling Unit After Removal from Skid

Page 7
FIGURE 2
REMOVAL OF UNIT FROM SKID

SHIPPING DAMAGE

Upon receipt of equipment, the carton should be checked for external signs of shipping damage. The skid must remain attached to the unit until the unit is ready for installation. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent.

UNIT REMOVAL FROM SKID

WARNING

This unit is heavy and requires more than one person to handle and remove from the skid. Check unit wheels to ensure that wheels are locked before removing from skid. Extreme caution must be taken to prevent injury to personnel and damage to the unit.

It is recommended that the unit not be removed from the skid with a fork lift.

The shipping brackets on each side of the unit must be removed and discarded. See Figure 2-A on Page 5. The return air grille panel can be removed to provide a place to hold the unit. The unit can be slid forward on the skid until the front wheels hang over the edge of the skid. See Figure 2-B. The unit can be tipped forward and slid down the edge of the skid until the front wheels touch the ground. See Figure 2-C. The wheels will not roll. They are shipped from the factory locked so they will not roll. The back of the skid will have to be held down to keep it from tipping up. The skid can be slid out from under the unit. The unit can then be set upright.

HANDLING UNIT AFTER REMOVAL FROM SKID

WARNING

Exercise extreme caution when pushing the unit on the rollers. Handle and push from the lower 1/3 of the unit. Insure that debris is not on the floor where the unit is to be moved on the rollers. Failure to do so could result in the unit tipping over and causing bodily injury and/or damage to the unit.

The unit will have to be turned sideways and removed from the skid to fit through a 36” doorway. If the door height allows, the unit can be slid sideways through the door.

If the unit can not be slid through the door, then the unit will have to be put on a cart and tipped down to roll through the door. It is recommended that an appliance cart by used with a strap to hold the unit on the cart. The wheels of the unit must be locked. If the wheels were allowed to roll, the unit could roll off the cart. The blade of the appliance cart should be slid under the wheels of the unit. See Figure 3. The strap of the appliance cart should be placed around the unit and strapped tightly. Help will be required to tip the unit back onto the cart. The unit can be leaned far enough back to be rolled through the door. Be careful when setting the unit back up to keep from damaging the unit.

HOLD SKID DOWN

MIS-1603

A SHIPPING BRACKETS

B FRONT WHEELS OVER EDGE

C FRONT WHEELS ON FLOOR

Manual 2100-416

Page 5

Image 7
Contents Model QC501 QC Series Installation Chilled Water Unit InstructionsContents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsFactory BUILT-IN Electric Heat Table Electrical SpecificationsQC Series Water Source General Information QC Model NomenclaturePsig Cooling Performance ChartUnit Dimensions Unit Removal from Skid Shipping DamageHandling Unit After Removal from Skid Proper Handling of Unit After Removal from Skid Minimum Installation HeightRemoval of Wall Bracket from Shipping Location GeneralInstallation of Unit Thru Wall with Wall Sleeve Ducted Application Installation with Free Blow PlenumFilter Location Duct WorkFilters Supply Duct ConnectionsOptional Rear Drain Condensate DrainSide Drain Side View Rear Drain TOP ViewCommercial Room Ventilator Option Barometric Fresh AIR Damper OptionalFresh AIR Damper Removal Removal of the Qtec Energy Recovery Ventilator Qtec Energy Recovery Ventilator OptionMounting the Unit Installation InstructionsRemoving Locking Screws from Wheels Side Trim Pieces Wall Mounting Bracket Component Location Wiring Main PowerWall Thermostats and Subbase Combinations Wiring LOW Voltage WiringFluid Connections Operating Voltage RangeLOW Voltage Connections Blower Motor LOW Voltage Wire Harness PlugLOW Voltage Connections for DDC Control Remote Thermostat Wiring Diagram Option Remote Thermostat Wiring Diagram Thermostat Option Optional CFM Important Installer NoteService Hints Start UPSymptom Troubleshooting ECM Blower MotorsSymptom Internal 2-WAY Valve Piping Valve DetailInternal 3-WAY Valve Piping

QC501 specifications

The Bard QC501 is an innovative piece of equipment designed specifically for quality control in various manufacturing processes. Known for its precision and efficiency, the QC501 serves multiple industrial sectors, including pharmaceuticals, food and beverage, cosmetics, and chemical manufacturing.

One of the standout features of the Bard QC501 is its state-of-the-art measurement technology. It utilizes advanced sensors and automated systems to ensure highly accurate readings. This precision is critical for industries where even the smallest deviation can result in significant issues, such as compromised product safety or regulatory violations.

The QC501 incorporates a user-friendly interface that simplifies operation for technicians and quality control personnel. Its touchscreen display provides real-time data, allowing users to monitor processes effectively and make on-the-fly adjustments as needed. This responsiveness ensures that production standards are consistently met, enhancing overall efficiency.

Another notable characteristic of the Bard QC501 is its data logging capabilities. The device is equipped with comprehensive software that records, analyzes, and generates reports on quality metrics. This feature is invaluable for facilitating thorough audits and maintaining compliance with stringent industry regulations. By providing a digital trail of quality data, the QC501 empowers companies to demonstrate their commitment to quality assurance.

In terms of connectivity, the QC501 is designed to integrate seamlessly into existing production lines. It offers multiple connectivity options, such as Ethernet and USB ports, making it compatible with various systems. This flexibility allows businesses to enhance their existing quality control processes without a complete overhaul of their infrastructure.

Durability is another critical aspect of the QC501. Manufactured with robust materials, it is designed to withstand the rigors of industrial environments. This reliability reduces downtime due to equipment failure, ensuring that production schedules remain on track.

In summary, the Bard QC501 stands out for its precision measurement technology, user-friendly interface, comprehensive data logging, seamless connectivity, and rugged durability. This combination of features makes it an essential tool for industries striving to maintain high quality standards while optimizing production efficiency. Investing in the Bard QC501 is a proactive step toward enhancing overall product quality and ensuring compliance with regulatory standards.