Agilent Technologies E4440A manual Key Overview

Page 31

Front and Rear Panel Features

Key Overview

Key Overview

The keys labeled FREQUENCY Channel, System, and Marker are all examples of front-panel keys. The front-panel keys are dark gray, light gray, green, or white in color. Front-panel keys that are white perform an immediate action rather than bringing up a menu. The only green key is the Preset key, which performs an analyzer reset (A summary of all front panel keys and their related menu keys can be found in user’s guide for your analyzer). Pressing most of the dark or light gray front-panel keys accesses menus of functions that are displayed along the right side of the display. These are called menu keys.

Menu keys list functions other than those accessed directly by the front panel keys. To activate a menu key function, press the key immediately to the right of the annotation on the screen. The menu keys that are displayed depend on which front-panel key is pressed and which menu level is enabled.

If a menu key function’s value can be changed, it is called an active function. The function label of the active function is highlighted after that key has been selected. For example, press AMPLITUDE Y Scale. This calls up the menu of related amplitude functions. Note the function labeled Ref Level (the default selected key in the Amplitude menu) is highlighted. Ref Level also appears in the active function block, indicating that it is the active amplitude function and can now be changed using any of the data entry controls.

A menu key with On and Off in its label can be used to turn the menu key’s function on or off. To turn the function on, press the menu key so that On is underlined. To turn the function off, press the menu key so that Off is underlined. In the manual, when On should be underlined, it will be indicated as Function (On).

A function with Auto and Man in the label can either be auto-coupled or have its value manually changed. The value of the function can be changed manually using the numeric keypad, knob, or step keys. To auto-couple a function, press the menu key so that Auto is underlined.

In some key menus, one key label will always be highlighted to show which key has been selected. For example, when you press Marker, you will access a menu of keys in which some of the keys are grouped together by a blue bar on the left side of the menu. The Normal key, which is the Marker menu default key, will be highlighted. When you press another key within the blue bar region, such as Delta, the highlight will move to that key to show it has been selected.

Front and Rear Panel Features

Chapter 2

31

Image 31
Contents Getting Started Guide Additional Information Contents Contents Installation and Setup Agilent Technologies Performance Spectrum Analyzer PSA Initial Inspection Description AccessoriesOr replacement see Contacting Agilent Technologies on If There Is a ProblemPower Requirements Power Requirements AC Power CordAC Power Cords Battery Information Information Screen Turning on the Analyzer for the First TimeIf Option 117 is Loaded in Memory Why Aren’t All the Personality Options Loaded in Memory?Using an External Reference Firmware Revision Manually Performing an Alignment Running Internal AlignmentsEquipment Printer Setup and OperationPCL3 Testing Printer Operation Interconnection and SetupTest Equipment and ESD Protecting Against Electrostatic DischargeAdditional Information about ESD Safety Information Front and Rear Panel Features Front Panel Overview Front-Panel Connectors and KeysFront Front Display AnnotationsTrigger & sweep modes Trace modes Phase noise optimization a Panel Rear-Panel FeaturesFront and Rear Key Overview Front and Rear Panel Features Do not dispose in domestic household waste Front and Rear Panel SymbolsMore information Making a Basic Measurement Basic Assumption Viewing a Signal onUsing Menu Keys Using the Front PanelEntering Data Attenuation Creating a User Preset Presetting the Spectrum AnalyzerDisabling User Preset Setting Reference Level and Center Frequency Viewing a SignalSetting Frequency Span 10 MHz Internal Reference Signal and Associated SpectrumChanging Reference Level Reading Frequency & AmplitudeA Marker on the 10 MHz Peak Valid Marker Count Range Improving Frequency AccuracyIncreasing Marker Frequency Accuracy Using Marker Counter Viewing Catalogs and Saving Viewing Catalogs and Saving Files Locating and viewing files in the catalog File Menu FunctionsCatalog Menu Creating a directory Viewing Catalogs and Saving Files Saving a File Set up the analyzer traceViewing Trace Viewing Traces 1, 2, Save the file\START\TEST1.TRC file saved File Loaded Loading a fileVerifying Trace Renaming a File Renaming a FileCopy Menu Copying a FileDeleting a File Using the Alpha Editor Options and Accessories Accessories see Ordering Options and AccessoriesOptions see Option Name Description Number OptionsMode includes the measurements Options 8PSK B7J Available only at time of purchase AC Probe AccessoriesOhm Load 50 Ohm/75 Ohm Minimum Loss PadHP/Agilent 11970 Series Harmonic Mixers Broadband Preamplifiers and Power AmplifiersGpib Cable USB/GPIB InterfaceHP/Agilent 11974 Series Preselected Millimeter Mixers Power SplittersRF and Transient Limiters Noise Sources for use with PSA Option Static Safe AccessoriesRF Bridges Ohm Transmission/Reflection Test KitCase of Difficulty Case of Difficulty Types of Messages Types of Spectrum Analyzer MessagesCheck the Basics Before Calling Agilent TechnologiesPSA or ESA Series at Contacting Agilent Technologies Read the WarrantyService Options Calling Agilent TechnologiesOther Packaging Returning an Analyzer for ServiceService Tag Original PackagingCase of Difficulty Index Index

E4440A specifications

Agilent Technologies has long been recognized for its cutting-edge solutions in the realm of electronic test and measurement, and the E4440A is no exception. This spectrum analyzer is part of Agilent's renowned X-Series, which has set benchmarks in performance and versatility for RF and microwave applications. The E4440A stands out for its reliability, accuracy, and advanced signal analysis capabilities.

One of the most notable features of the E4440A is its exceptional frequency range. The device covers frequencies from 3 Hz to 9 kHz, allowing it to handle a wide array of signals, from low-frequency communications to high-frequency RF applications. By offering such broad bandwidth, the E4440A caters to various sectors including telecommunications, aerospace, and research and development.

In terms of specifications, the E4440A boasts a maximum amplitude measurement accuracy of ±0.7 dB, which is crucial for detailed signal analysis. Its 1 Hz to 30 MHz demodulation bandwidth allows users to accurately analyze complex modulated signals, making it ideal for capturing and decoding various communication formats.

Built on Agilent's exclusive technology, the E4440A integrates the advanced "Digital Signal Processing" capabilities, enhancing its measurement precision and speed. This technology not only improves the analyzer's dynamic range but also allows for quick identification and analysis of signals, ensuring that engineers can optimize performance and troubleshoot issues more effectively.

A unique characteristic of the E4440A is its robust user interface. The spectrum analyzer features a high-resolution display, which provides clear visualizations of signals. Additionally, its intuitive navigation simplifies operation, enabling both seasoned engineers and newcomers to utilize the device effectively without extensive training.

The E4440A is also equipped with a variety of built-in measurement capabilities, including distortion, modulation, and phase noise analysis. These tools empower users to assess the quality of their transmission systems comprehensively, thus facilitating improvements and innovations in design.

In conclusion, Agilent Technologies E4440A stands as a versatile spectrum analyzer that combines cutting-edge technology with user-friendly features. Its broad frequency range, high accuracy, and advanced analysis capabilities make it an essential tool for professionals in the RF and microwave sectors. Whether for research, development, or testing, the E4440A delivers the precision and reliability that engineers expect from Agilent Technologies.