Agilent Technologies E4440A manual Options

Page 67

 

 

Options and Accessories

 

 

 

Options

 

 

 

 

 

 

Option

Name

Description

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

204

1xEV-DO Measurement

Provides 1xEV transmitter measurements:

 

 

 

Personality

channel power

 

 

 

 

 

 

 

 

ACPR

 

 

 

 

intermodulation

 

 

 

 

spectrum emission mask

 

 

 

 

occupied BW

 

 

 

 

code domain power (pilot)

 

 

 

 

EVM (pilot)

 

 

 

 

 

 

 

QPSK EVM

 

 

 

 

power statistics CCDF

 

 

 

 

Requires Option B7J hardware.

 

Options

 

 

 

 

210

HSDPA/HSUPA

Provides High-Speed Downlink/Uplink Packet Access to

 

 

Measurement Personality

support 16 QAM and modulation accuracy. Requires Option

 

 

 

BAF.

 

and

 

 

Requires Option B7J hardware.

 

 

 

 

Accessories

 

 

 

 

211

TD-SCDMA Measurement

Measures the power profile of TD SCDMA BTS and MS.

 

 

 

 

Personality

Requires Option B78 measurement personality and Option B7J

 

 

 

 

hardware.

 

 

 

 

 

 

 

214

1xEV-DV

Supports 8 PSK and 16 QAM modulation analysis. Requires

 

 

 

 

Option B78. Includes measurements:

 

 

 

 

Composite Rho

 

 

 

 

 

 

 

Code Domain tests

 

 

 

 

Requires Option B7J hardware.

 

 

 

 

 

 

 

215

External Source Control

Adds external source control to the PSA analyzer for

 

 

 

Measurement Personality

stimulus-response measurements.

 

 

 

 

 

 

 

217

WLAN Measurement

Provides WLAN transmitter measurements for 802.11 a/b/g.

 

 

(E4440A,

Personality

Requires Option 122 or 140. Also requires Option 123 for center

 

 

 

frequencies above 3 GHz.

 

 

43A, & 45A

 

 

 

 

 

 

 

only)

 

 

 

 

 

 

 

 

 

219

Noise Figure Measurement

Provides noise figure measurements:

 

 

 

Personality

Limit lines

 

 

 

 

 

 

 

 

Loss compensation

 

 

 

 

Extended frequency (measures up/down converters)

 

 

 

 

You need the preamp option: Option 1DS to have specified

 

 

 

 

performance only below 3 GHz, or Option 110 to have specified

 

 

 

 

performance over the entire frequency range.

 

 

 

 

 

 

 

226

Phase Noise Measurement

Provides phase noise measurements:

 

 

 

Personality

Monitor spectrum

 

 

 

 

 

 

 

 

Spot frequency

 

 

 

 

Log plot

 

 

 

 

 

 

 

Chapter 5

67

Image 67
Contents Getting Started Guide Additional Information Contents Contents Installation and Setup Agilent Technologies Performance Spectrum Analyzer PSA Initial Inspection Description AccessoriesOr replacement see Contacting Agilent Technologies on If There Is a ProblemPower Requirements Power Requirements AC Power CordAC Power Cords Battery Information Information Screen Turning on the Analyzer for the First TimeIf Option 117 is Loaded in Memory Why Aren’t All the Personality Options Loaded in Memory?Using an External Reference Firmware Revision Manually Performing an Alignment Running Internal AlignmentsEquipment Printer Setup and OperationPCL3 Testing Printer Operation Interconnection and SetupTest Equipment and ESD Protecting Against Electrostatic DischargeAdditional Information about ESD Safety Information Front and Rear Panel Features Front Panel Overview Front-Panel Connectors and KeysFront Front Display AnnotationsTrigger & sweep modes Trace modes Phase noise optimization a Panel Rear-Panel FeaturesFront and Rear Key Overview Front and Rear Panel Features Do not dispose in domestic household waste Front and Rear Panel SymbolsMore information Making a Basic Measurement Basic Assumption Viewing a Signal onUsing Menu Keys Using the Front PanelEntering Data Attenuation Creating a User Preset Presetting the Spectrum AnalyzerDisabling User Preset Setting Reference Level and Center Frequency Viewing a SignalSetting Frequency Span 10 MHz Internal Reference Signal and Associated SpectrumChanging Reference Level Reading Frequency & AmplitudeA Marker on the 10 MHz Peak Valid Marker Count Range Improving Frequency AccuracyIncreasing Marker Frequency Accuracy Using Marker Counter Viewing Catalogs and Saving Viewing Catalogs and Saving Files Locating and viewing files in the catalog File Menu FunctionsCatalog Menu Creating a directory Viewing Catalogs and Saving Files Saving a File Set up the analyzer traceViewing Trace Viewing Traces 1, 2, Save the file\START\TEST1.TRC file saved File Loaded Loading a fileVerifying Trace Renaming a File Renaming a FileCopy Menu Copying a FileDeleting a File Using the Alpha Editor Options and Accessories Accessories see Ordering Options and AccessoriesOptions see Option Name Description Number OptionsMode includes the measurements Options 8PSK B7J Available only at time of purchase AC Probe AccessoriesOhm Load 50 Ohm/75 Ohm Minimum Loss PadHP/Agilent 11970 Series Harmonic Mixers Broadband Preamplifiers and Power AmplifiersGpib Cable USB/GPIB InterfaceHP/Agilent 11974 Series Preselected Millimeter Mixers Power SplittersRF and Transient Limiters Noise Sources for use with PSA Option Static Safe AccessoriesRF Bridges Ohm Transmission/Reflection Test KitCase of Difficulty Case of Difficulty Types of Messages Types of Spectrum Analyzer MessagesCheck the Basics Before Calling Agilent TechnologiesPSA or ESA Series at Contacting Agilent Technologies Read the WarrantyService Options Calling Agilent TechnologiesOther Packaging Returning an Analyzer for ServiceService Tag Original PackagingCase of Difficulty Index Index

E4440A specifications

Agilent Technologies has long been recognized for its cutting-edge solutions in the realm of electronic test and measurement, and the E4440A is no exception. This spectrum analyzer is part of Agilent's renowned X-Series, which has set benchmarks in performance and versatility for RF and microwave applications. The E4440A stands out for its reliability, accuracy, and advanced signal analysis capabilities.

One of the most notable features of the E4440A is its exceptional frequency range. The device covers frequencies from 3 Hz to 9 kHz, allowing it to handle a wide array of signals, from low-frequency communications to high-frequency RF applications. By offering such broad bandwidth, the E4440A caters to various sectors including telecommunications, aerospace, and research and development.

In terms of specifications, the E4440A boasts a maximum amplitude measurement accuracy of ±0.7 dB, which is crucial for detailed signal analysis. Its 1 Hz to 30 MHz demodulation bandwidth allows users to accurately analyze complex modulated signals, making it ideal for capturing and decoding various communication formats.

Built on Agilent's exclusive technology, the E4440A integrates the advanced "Digital Signal Processing" capabilities, enhancing its measurement precision and speed. This technology not only improves the analyzer's dynamic range but also allows for quick identification and analysis of signals, ensuring that engineers can optimize performance and troubleshoot issues more effectively.

A unique characteristic of the E4440A is its robust user interface. The spectrum analyzer features a high-resolution display, which provides clear visualizations of signals. Additionally, its intuitive navigation simplifies operation, enabling both seasoned engineers and newcomers to utilize the device effectively without extensive training.

The E4440A is also equipped with a variety of built-in measurement capabilities, including distortion, modulation, and phase noise analysis. These tools empower users to assess the quality of their transmission systems comprehensively, thus facilitating improvements and innovations in design.

In conclusion, Agilent Technologies E4440A stands as a versatile spectrum analyzer that combines cutting-edge technology with user-friendly features. Its broad frequency range, high accuracy, and advanced analysis capabilities make it an essential tool for professionals in the RF and microwave sectors. Whether for research, development, or testing, the E4440A delivers the precision and reliability that engineers expect from Agilent Technologies.