Agilent Technologies E4440A manual RF Bridges, Ohm Transmission/Reflection Test Kit

Page 74

Options and Accessories

Options and Accessories

Accessories

RF Bridges

The Agilent 86205A 50 RF bridge and 86207A 75 RF bridge can be used with the ESA series to make reflection measurements using an analyzer with tracking generator Option 1DN or 1DQ or with an external signal generator. The Agilent 86205A 50 RF bridge can be used with the PSA series to make reflection measurements using an analyzer with the external source control, Option 215.

These external directional bridges offer high directivity and excellent port match. The 86205A operates over a frequency range of 300 kHz to 6 GHz. The 86207A operates over a frequency range of 300 kHz to 3 GHz.

50 Ohm Transmission/Reflection Test Kit

The Agilent 87512A provides the accessories to measure the reflection and transmission characteristics of 50 devices up to 2 GHz. These accessories use type N connectors. The kit contains a directional bridge, 2 cables and precision short/load terminations for calibration.

Static Safe Accessories

9300-0797 3M static control mat 0.6 m × 1.2 m (2 ft. × 4 ft.) with a

4.6cm (15 ft.) ground wire. Does not include wrist strap or cord

9300-1367 Wrist-strap, color black, stainless steel. Four adjustable

links and a 7 mm post-type connection.

9300-0980 Wrist-strap cord 1.5 m (5 ft.)

9300-1308 ESD heel-strap (reusable 6 to 12 months)

Noise Sources (for use with PSA Option 119)

Agilent 346A 10 MHz to 18 GHz noise source with 5 dB ENR (nominal)

Agilent 346B 10 MHz to 18 GHz noise source with 15 dB ENR (nominal)

Agilent 346C 10 MHz to 26.5 GHz noise source with 15 dB ENR (nominal)

74

Chapter 5

Image 74
Contents Getting Started Guide Additional Information Contents Contents Installation and Setup Agilent Technologies Performance Spectrum Analyzer PSA Description Accessories Initial InspectionIf There Is a Problem Or replacement see Contacting Agilent Technologies onPower Requirements AC Power Cord Power RequirementsAC Power Cords Battery Information Turning on the Analyzer for the First Time Information ScreenWhy Aren’t All the Personality Options Loaded in Memory? If Option 117 is Loaded in MemoryUsing an External Reference Firmware Revision Running Internal Alignments Manually Performing an AlignmentPrinter Setup and Operation EquipmentPCL3 Interconnection and Setup Testing Printer OperationAdditional Information about ESD Protecting Against Electrostatic DischargeTest Equipment and ESD Safety Information Front and Rear Panel Features Front-Panel Connectors and Keys Front Panel OverviewFront Display Annotations FrontTrigger & sweep modes Trace modes Phase noise optimization a Rear-Panel Features PanelFront and Rear Key Overview Front and Rear Panel Features Front and Rear Panel Symbols Do not dispose in domestic household wasteMore information Making a Basic Measurement Viewing a Signal on Basic AssumptionEntering Data Using the Front PanelUsing Menu Keys Attenuation Disabling User Preset Presetting the Spectrum AnalyzerCreating a User Preset Viewing a Signal Setting Reference Level and Center Frequency10 MHz Internal Reference Signal and Associated Spectrum Setting Frequency SpanReading Frequency & Amplitude Changing Reference LevelA Marker on the 10 MHz Peak Improving Frequency Accuracy Valid Marker Count RangeIncreasing Marker Frequency Accuracy Using Marker Counter Viewing Catalogs and Saving Viewing Catalogs and Saving Files File Menu Functions Locating and viewing files in the catalogCatalog Menu Creating a directory Viewing Catalogs and Saving Files Set up the analyzer trace Saving a FileViewing Trace Save the file Viewing Traces 1, 2,\START\TEST1.TRC file saved Loading a file File LoadedVerifying Trace Renaming a File Renaming a FileCopying a File Copy MenuDeleting a File Using the Alpha Editor Options and Accessories Options see Ordering Options and AccessoriesAccessories see Options Option Name Description NumberMode includes the measurements Options 8PSK B7J Available only at time of purchase 50 Ohm/75 Ohm Minimum Loss Pad AccessoriesOhm Load AC ProbeUSB/GPIB Interface Broadband Preamplifiers and Power AmplifiersGpib Cable HP/Agilent 11970 Series Harmonic MixersRF and Transient Limiters Power SplittersHP/Agilent 11974 Series Preselected Millimeter Mixers Ohm Transmission/Reflection Test Kit Static Safe AccessoriesRF Bridges Noise Sources for use with PSA OptionCase of Difficulty Case of Difficulty Types of Spectrum Analyzer Messages Types of MessagesBefore Calling Agilent Technologies Check the BasicsPSA or ESA Series at Calling Agilent Technologies Read the WarrantyService Options Contacting Agilent TechnologiesOriginal Packaging Returning an Analyzer for ServiceService Tag Other PackagingCase of Difficulty Index Index

E4440A specifications

Agilent Technologies has long been recognized for its cutting-edge solutions in the realm of electronic test and measurement, and the E4440A is no exception. This spectrum analyzer is part of Agilent's renowned X-Series, which has set benchmarks in performance and versatility for RF and microwave applications. The E4440A stands out for its reliability, accuracy, and advanced signal analysis capabilities.

One of the most notable features of the E4440A is its exceptional frequency range. The device covers frequencies from 3 Hz to 9 kHz, allowing it to handle a wide array of signals, from low-frequency communications to high-frequency RF applications. By offering such broad bandwidth, the E4440A caters to various sectors including telecommunications, aerospace, and research and development.

In terms of specifications, the E4440A boasts a maximum amplitude measurement accuracy of ±0.7 dB, which is crucial for detailed signal analysis. Its 1 Hz to 30 MHz demodulation bandwidth allows users to accurately analyze complex modulated signals, making it ideal for capturing and decoding various communication formats.

Built on Agilent's exclusive technology, the E4440A integrates the advanced "Digital Signal Processing" capabilities, enhancing its measurement precision and speed. This technology not only improves the analyzer's dynamic range but also allows for quick identification and analysis of signals, ensuring that engineers can optimize performance and troubleshoot issues more effectively.

A unique characteristic of the E4440A is its robust user interface. The spectrum analyzer features a high-resolution display, which provides clear visualizations of signals. Additionally, its intuitive navigation simplifies operation, enabling both seasoned engineers and newcomers to utilize the device effectively without extensive training.

The E4440A is also equipped with a variety of built-in measurement capabilities, including distortion, modulation, and phase noise analysis. These tools empower users to assess the quality of their transmission systems comprehensively, thus facilitating improvements and innovations in design.

In conclusion, Agilent Technologies E4440A stands as a versatile spectrum analyzer that combines cutting-edge technology with user-friendly features. Its broad frequency range, high accuracy, and advanced analysis capabilities make it an essential tool for professionals in the RF and microwave sectors. Whether for research, development, or testing, the E4440A delivers the precision and reliability that engineers expect from Agilent Technologies.