Agilent Technologies E4440A manual HP/Agilent 11974 Series Preselected Millimeter Mixers

Page 73

Options and Accessories

Accessories

HP/Agilent 11974 Series Preselected Millimeter Mixers

11974 Series preselected millimeter mixers are available to extend the frequency range of analyzers with Option AYZ (external mixing) up to 75 GHz. Preselection reduces mixer overload from broadband signals, reduces radiation of local oscillator harmonics back to the device under test, and reduces the level of image and multiple responses displayed. The following four models are available:

Table 5-2

HP/Agilent

Frequency Range

Options

Model Number

 

 

 

 

 

 

11974A

26.5 to 40.0 GHz

and

 

 

11974Q

33.0 to 50.0 GHz

Accessories

 

 

11974U

40.0 to 60.0 GHz

 

 

 

 

11974V

50.0 to 75.0 GHz

 

 

 

 

RF and Transient Limiters

The Agilent 11867A and N9355B RF Limiters protect the analyzer input circuits from damage due to high power levels. The 11867A operates over a frequency range of dc to 1800 MHz and begins reflecting signal levels over 1 mW up to 10 W average power and 100 watts peak power. The N9355B microwave limiter (0.1 to 18 GHz) guards against input signals over 1 milliwatt up to 1 watt average power and 10 watts peak power.

The Agilent 11947A Transient Limiter protects the analyzer input circuits from damage due to signal transients. It specifically is needed for use with a line impedance stabilization network (LISN). It operates over a frequency range of 9 kHz to 200 MHz, with 10 dB of insertion loss.

Power Splitters

The Agilent 11667A/B/C power splitters are two-resister type splitters that provide excellent output SWR, at 50 impedance. The tracking between the two output arms, over a broad frequency range, allows wideband measurements to be made with a minimum of uncertainty.

11667A: DC to 18 GHz

11667B: DC to 26.5 GHz

11667C: DC to 50 GHz

Chapter 5

73

Image 73
Contents Getting Started Guide Additional Information Contents Contents Installation and Setup Agilent Technologies Performance Spectrum Analyzer PSA Initial Inspection Description AccessoriesOr replacement see Contacting Agilent Technologies on If There Is a ProblemPower Requirements Power Requirements AC Power CordAC Power Cords Battery Information Information Screen Turning on the Analyzer for the First TimeIf Option 117 is Loaded in Memory Why Aren’t All the Personality Options Loaded in Memory?Using an External Reference Firmware Revision Manually Performing an Alignment Running Internal AlignmentsEquipment Printer Setup and OperationPCL3 Testing Printer Operation Interconnection and SetupTest Equipment and ESD Protecting Against Electrostatic DischargeAdditional Information about ESD Safety Information Front and Rear Panel Features Front Panel Overview Front-Panel Connectors and KeysFront Front Display AnnotationsTrigger & sweep modes Trace modes Phase noise optimization a Panel Rear-Panel FeaturesFront and Rear Key Overview Front and Rear Panel Features Do not dispose in domestic household waste Front and Rear Panel SymbolsMore information Making a Basic Measurement Basic Assumption Viewing a Signal onUsing Menu Keys Using the Front PanelEntering Data Attenuation Creating a User Preset Presetting the Spectrum AnalyzerDisabling User Preset Setting Reference Level and Center Frequency Viewing a SignalSetting Frequency Span 10 MHz Internal Reference Signal and Associated SpectrumChanging Reference Level Reading Frequency & AmplitudeA Marker on the 10 MHz Peak Valid Marker Count Range Improving Frequency AccuracyIncreasing Marker Frequency Accuracy Using Marker Counter Viewing Catalogs and Saving Viewing Catalogs and Saving Files Locating and viewing files in the catalog File Menu FunctionsCatalog Menu Creating a directory Viewing Catalogs and Saving Files Saving a File Set up the analyzer traceViewing Trace Viewing Traces 1, 2, Save the file\START\TEST1.TRC file saved File Loaded Loading a fileVerifying Trace Renaming a File Renaming a FileCopy Menu Copying a FileDeleting a File Using the Alpha Editor Options and Accessories Accessories see Ordering Options and AccessoriesOptions see Option Name Description Number OptionsMode includes the measurements Options 8PSK B7J Available only at time of purchase Ohm Load Accessories50 Ohm/75 Ohm Minimum Loss Pad AC ProbeGpib Cable Broadband Preamplifiers and Power AmplifiersUSB/GPIB Interface HP/Agilent 11970 Series Harmonic MixersHP/Agilent 11974 Series Preselected Millimeter Mixers Power SplittersRF and Transient Limiters RF Bridges Static Safe AccessoriesOhm Transmission/Reflection Test Kit Noise Sources for use with PSA OptionCase of Difficulty Case of Difficulty Types of Messages Types of Spectrum Analyzer MessagesCheck the Basics Before Calling Agilent TechnologiesPSA or ESA Series at Service Options Read the WarrantyCalling Agilent Technologies Contacting Agilent TechnologiesService Tag Returning an Analyzer for ServiceOriginal Packaging Other PackagingCase of Difficulty Index Index

E4440A specifications

Agilent Technologies has long been recognized for its cutting-edge solutions in the realm of electronic test and measurement, and the E4440A is no exception. This spectrum analyzer is part of Agilent's renowned X-Series, which has set benchmarks in performance and versatility for RF and microwave applications. The E4440A stands out for its reliability, accuracy, and advanced signal analysis capabilities.

One of the most notable features of the E4440A is its exceptional frequency range. The device covers frequencies from 3 Hz to 9 kHz, allowing it to handle a wide array of signals, from low-frequency communications to high-frequency RF applications. By offering such broad bandwidth, the E4440A caters to various sectors including telecommunications, aerospace, and research and development.

In terms of specifications, the E4440A boasts a maximum amplitude measurement accuracy of ±0.7 dB, which is crucial for detailed signal analysis. Its 1 Hz to 30 MHz demodulation bandwidth allows users to accurately analyze complex modulated signals, making it ideal for capturing and decoding various communication formats.

Built on Agilent's exclusive technology, the E4440A integrates the advanced "Digital Signal Processing" capabilities, enhancing its measurement precision and speed. This technology not only improves the analyzer's dynamic range but also allows for quick identification and analysis of signals, ensuring that engineers can optimize performance and troubleshoot issues more effectively.

A unique characteristic of the E4440A is its robust user interface. The spectrum analyzer features a high-resolution display, which provides clear visualizations of signals. Additionally, its intuitive navigation simplifies operation, enabling both seasoned engineers and newcomers to utilize the device effectively without extensive training.

The E4440A is also equipped with a variety of built-in measurement capabilities, including distortion, modulation, and phase noise analysis. These tools empower users to assess the quality of their transmission systems comprehensively, thus facilitating improvements and innovations in design.

In conclusion, Agilent Technologies E4440A stands as a versatile spectrum analyzer that combines cutting-edge technology with user-friendly features. Its broad frequency range, high accuracy, and advanced analysis capabilities make it an essential tool for professionals in the RF and microwave sectors. Whether for research, development, or testing, the E4440A delivers the precision and reliability that engineers expect from Agilent Technologies.