Agilent Technologies E4440A manual Before Calling Agilent Technologies, Check the Basics

Page 78

In Case of Difficulty

NOTE

NOTE

In Case of Difficulty

Before Calling Agilent Technologies

Before Calling Agilent Technologies

Check the Basics

Is there power at the receptacle?

Make sure there is no disk in the front-panel disk drive.

Is the analyzer turned on? Check to see if the green LED above the power switch is on. Also, listen for internal fan noise to determine if the analyzer cooling fans are running.

If other equipment, cables, and connectors are being used with your spectrum analyzer, make sure they are connected properly and operating correctly.

Review the measurement procedures being performed when the problem first appeared. Are all of the settings correct?

If the analyzer is not functioning as expected, return the analyzer to a known state by pressing Preset, and Factory Preset (if displayed).

Some analyzer settings are not affected by a Preset. If you wish to reset the analyzer configuration to the state it was in when it was originally sent from the factory, press System, Power On/Preset, Preset Type, Factory. Then press the green Preset key on the front panel.

Is the measurement being performed, and the results that are expected, within the specifications and capabilities of the analyzer? Refer to the Specifications guide for your analyzer.

If the analyzer is not communicating via the LAN connection, check for the presence of blinking yellow LEDs on the rear panel LAN connector. If the Rx (receive) LED is not blinking, check the LAN cable and LAN integrity.

The analyzer must be powered on with the LAN already connected in order to recognize the LAN port.

To meet specifications, the analyzer must be aligned. Either the Auto Align (On) feature must be selected (press System, Alignments, Auto Align, On), or the analyzer must be manually aligned at least once every 24 hours, or whenever the temperature changes more than 3°C. When Auto Align, On is selected, the AA screen annotation appears on the left edge of the display.

78

Chapter 6

Image 78
Contents Getting Started Guide Additional Information Contents Contents Installation and Setup Agilent Technologies Performance Spectrum Analyzer PSA Description Accessories Initial InspectionIf There Is a Problem Or replacement see Contacting Agilent Technologies onPower Requirements AC Power Cord Power RequirementsAC Power Cords Battery Information Turning on the Analyzer for the First Time Information ScreenWhy Aren’t All the Personality Options Loaded in Memory? If Option 117 is Loaded in MemoryUsing an External Reference Firmware Revision Running Internal Alignments Manually Performing an AlignmentPrinter Setup and Operation EquipmentPCL3 Interconnection and Setup Testing Printer OperationProtecting Against Electrostatic Discharge Test Equipment and ESDAdditional Information about ESD Safety Information Front and Rear Panel Features Front-Panel Connectors and Keys Front Panel OverviewFront Display Annotations FrontTrigger & sweep modes Trace modes Phase noise optimization a Rear-Panel Features PanelFront and Rear Key Overview Front and Rear Panel Features Front and Rear Panel Symbols Do not dispose in domestic household wasteMore information Making a Basic Measurement Viewing a Signal on Basic AssumptionUsing the Front Panel Using Menu KeysEntering Data Attenuation Presetting the Spectrum Analyzer Creating a User PresetDisabling User Preset Viewing a Signal Setting Reference Level and Center Frequency10 MHz Internal Reference Signal and Associated Spectrum Setting Frequency SpanReading Frequency & Amplitude Changing Reference LevelA Marker on the 10 MHz Peak Improving Frequency Accuracy Valid Marker Count RangeIncreasing Marker Frequency Accuracy Using Marker Counter Viewing Catalogs and Saving Viewing Catalogs and Saving Files File Menu Functions Locating and viewing files in the catalogCatalog Menu Creating a directory Viewing Catalogs and Saving Files Set up the analyzer trace Saving a FileViewing Trace Save the file Viewing Traces 1, 2,\START\TEST1.TRC file saved Loading a file File LoadedVerifying Trace Renaming a File Renaming a FileCopying a File Copy MenuDeleting a File Using the Alpha Editor Options and Accessories Ordering Options and Accessories Accessories seeOptions see Options Option Name Description NumberMode includes the measurements Options 8PSK B7J Available only at time of purchase 50 Ohm/75 Ohm Minimum Loss Pad AccessoriesOhm Load AC ProbeUSB/GPIB Interface Broadband Preamplifiers and Power AmplifiersGpib Cable HP/Agilent 11970 Series Harmonic MixersPower Splitters HP/Agilent 11974 Series Preselected Millimeter MixersRF and Transient Limiters Ohm Transmission/Reflection Test Kit Static Safe AccessoriesRF Bridges Noise Sources for use with PSA OptionCase of Difficulty Case of Difficulty Types of Spectrum Analyzer Messages Types of MessagesBefore Calling Agilent Technologies Check the BasicsPSA or ESA Series at Calling Agilent Technologies Read the WarrantyService Options Contacting Agilent TechnologiesOriginal Packaging Returning an Analyzer for ServiceService Tag Other PackagingCase of Difficulty Index Index

E4440A specifications

Agilent Technologies has long been recognized for its cutting-edge solutions in the realm of electronic test and measurement, and the E4440A is no exception. This spectrum analyzer is part of Agilent's renowned X-Series, which has set benchmarks in performance and versatility for RF and microwave applications. The E4440A stands out for its reliability, accuracy, and advanced signal analysis capabilities.

One of the most notable features of the E4440A is its exceptional frequency range. The device covers frequencies from 3 Hz to 9 kHz, allowing it to handle a wide array of signals, from low-frequency communications to high-frequency RF applications. By offering such broad bandwidth, the E4440A caters to various sectors including telecommunications, aerospace, and research and development.

In terms of specifications, the E4440A boasts a maximum amplitude measurement accuracy of ±0.7 dB, which is crucial for detailed signal analysis. Its 1 Hz to 30 MHz demodulation bandwidth allows users to accurately analyze complex modulated signals, making it ideal for capturing and decoding various communication formats.

Built on Agilent's exclusive technology, the E4440A integrates the advanced "Digital Signal Processing" capabilities, enhancing its measurement precision and speed. This technology not only improves the analyzer's dynamic range but also allows for quick identification and analysis of signals, ensuring that engineers can optimize performance and troubleshoot issues more effectively.

A unique characteristic of the E4440A is its robust user interface. The spectrum analyzer features a high-resolution display, which provides clear visualizations of signals. Additionally, its intuitive navigation simplifies operation, enabling both seasoned engineers and newcomers to utilize the device effectively without extensive training.

The E4440A is also equipped with a variety of built-in measurement capabilities, including distortion, modulation, and phase noise analysis. These tools empower users to assess the quality of their transmission systems comprehensively, thus facilitating improvements and innovations in design.

In conclusion, Agilent Technologies E4440A stands as a versatile spectrum analyzer that combines cutting-edge technology with user-friendly features. Its broad frequency range, high accuracy, and advanced analysis capabilities make it an essential tool for professionals in the RF and microwave sectors. Whether for research, development, or testing, the E4440A delivers the precision and reliability that engineers expect from Agilent Technologies.