Agilent Technologies E4440A manual Options, Option Name Description Number

Page 65

 

 

 

 

 

Options and Accessories

 

 

 

 

 

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

Option

 

 

Name

Description

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual Set on CD-ROM

The documentation CD-ROM contains the standard

 

 

 

0B0

documentation set as well as Adobe Acrobat Reader with

 

 

 

 

 

 

Only

 

 

 

 

Search.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

 

Additional Manual Set

An additional set of the standard documentation shipped with

 

 

 

 

 

 

0B1

 

 

 

the analyzer. See “Initial Inspection” on page 7 for information

 

 

 

 

 

 

 

about the standard documentation set.

 

 

 

 

 

 

 

 

 

and

 

 

Service Documentation

The Service guide describes assembly-level troubleshooting

 

 

 

 

 

 

0BW

Front Handle Kit

procedures, provides a parts list, and documents post-repair

 

Accessories

 

1CN

Available as P/N 5063-9228.

 

 

 

 

 

 

procedures.

 

 

 

1CM

Rack Mount Kit

Includes rack mount flanges and hardware. Used to rack mount

 

 

 

 

 

 

analyzers without front handles (available as P/N 5063-9215).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rack Mount Kit with

Includes the parts necessary to rack mount an analyzer with

 

 

 

1CP

Handles

front handles attached (available as P/N 5063-9222). (Includes

 

 

 

 

 

 

 

handles.)

 

 

 

 

 

 

 

 

 

1CR

Rack Slide Kit

Available as P/N E4406-60115. Rack slides allow the analyzer

 

 

 

 

 

 

to be pulled out while the analyzer is secured to the rack.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preamplifier

An internal preamplifier assembly. Not required when Option

 

 

 

1DS

 

 

 

110 is installed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency Range: 100 kHz to 3 GHz

 

 

 

 

 

 

 

 

 

015

6 GHz Measurement

Includes accessories necessary to set up return loss and

 

 

 

Accessory Kit

loss/gain measurements. Used with Option 215.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Audio Input, 100 k

Audio signal analysis capability that works with the Option 233

 

 

 

107

 

 

 

Measuring Receiver System. Available in all models. Option

 

 

 

 

 

 

107 cannot be installed if Option 122 or 140 is installed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Requires Option 233.

 

 

 

 

 

 

 

 

 

 

RF/µW Internal

An internal preamplifier assembly that covers all frequency

 

 

 

110

Preamplifier

bands. Available in all models. Option 110 cannot be installed if

 

 

 

 

 

 

Option 1DS is installed.

 

 

 

 

 

 

 

Frequency Range: 100 kHz to 50 GHz

 

 

 

 

 

 

 

 

 

111

USB Device Side I/O

Provides a rear-panel USB interface connector (device side I/O

 

 

 

Interface

only).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

512 Mb User Memory

Provides additional memory to accommodate a greater number

 

 

 

115

 

 

 

of applications. Available in all models. Option 115 cannot be

 

 

 

 

 

 

 

installed if Option 117 is installed.

 

 

 

 

 

 

 

 

 

 

Chapter 5

65

Image 65
Contents Getting Started Guide Additional Information Contents Contents Installation and Setup Agilent Technologies Performance Spectrum Analyzer PSA Initial Inspection Description AccessoriesOr replacement see Contacting Agilent Technologies on If There Is a ProblemPower Requirements Power Requirements AC Power CordAC Power Cords Battery Information Information Screen Turning on the Analyzer for the First TimeIf Option 117 is Loaded in Memory Why Aren’t All the Personality Options Loaded in Memory?Using an External Reference Firmware Revision Manually Performing an Alignment Running Internal AlignmentsEquipment Printer Setup and OperationPCL3 Testing Printer Operation Interconnection and SetupAdditional Information about ESD Protecting Against Electrostatic DischargeTest Equipment and ESD Safety Information Front and Rear Panel Features Front Panel Overview Front-Panel Connectors and KeysFront Front Display AnnotationsTrigger & sweep modes Trace modes Phase noise optimization a Panel Rear-Panel FeaturesFront and Rear Key Overview Front and Rear Panel Features Do not dispose in domestic household waste Front and Rear Panel SymbolsMore information Making a Basic Measurement Basic Assumption Viewing a Signal onEntering Data Using the Front PanelUsing Menu Keys Attenuation Disabling User Preset Presetting the Spectrum AnalyzerCreating a User Preset Setting Reference Level and Center Frequency Viewing a SignalSetting Frequency Span 10 MHz Internal Reference Signal and Associated SpectrumChanging Reference Level Reading Frequency & AmplitudeA Marker on the 10 MHz Peak Valid Marker Count Range Improving Frequency AccuracyIncreasing Marker Frequency Accuracy Using Marker Counter Viewing Catalogs and Saving Viewing Catalogs and Saving Files Locating and viewing files in the catalog File Menu FunctionsCatalog Menu Creating a directory Viewing Catalogs and Saving Files Saving a File Set up the analyzer traceViewing Trace Viewing Traces 1, 2, Save the file\START\TEST1.TRC file saved File Loaded Loading a fileVerifying Trace Renaming a File Renaming a FileCopy Menu Copying a FileDeleting a File Using the Alpha Editor Options and Accessories Options see Ordering Options and AccessoriesAccessories see Option Name Description Number OptionsMode includes the measurements Options 8PSK B7J Available only at time of purchase Ohm Load Accessories50 Ohm/75 Ohm Minimum Loss Pad AC ProbeGpib Cable Broadband Preamplifiers and Power AmplifiersUSB/GPIB Interface HP/Agilent 11970 Series Harmonic MixersRF and Transient Limiters Power SplittersHP/Agilent 11974 Series Preselected Millimeter Mixers RF Bridges Static Safe AccessoriesOhm Transmission/Reflection Test Kit Noise Sources for use with PSA OptionCase of Difficulty Case of Difficulty Types of Messages Types of Spectrum Analyzer MessagesCheck the Basics Before Calling Agilent TechnologiesPSA or ESA Series at Service Options Read the WarrantyCalling Agilent Technologies Contacting Agilent TechnologiesService Tag Returning an Analyzer for ServiceOriginal Packaging Other PackagingCase of Difficulty Index Index

E4440A specifications

Agilent Technologies has long been recognized for its cutting-edge solutions in the realm of electronic test and measurement, and the E4440A is no exception. This spectrum analyzer is part of Agilent's renowned X-Series, which has set benchmarks in performance and versatility for RF and microwave applications. The E4440A stands out for its reliability, accuracy, and advanced signal analysis capabilities.

One of the most notable features of the E4440A is its exceptional frequency range. The device covers frequencies from 3 Hz to 9 kHz, allowing it to handle a wide array of signals, from low-frequency communications to high-frequency RF applications. By offering such broad bandwidth, the E4440A caters to various sectors including telecommunications, aerospace, and research and development.

In terms of specifications, the E4440A boasts a maximum amplitude measurement accuracy of ±0.7 dB, which is crucial for detailed signal analysis. Its 1 Hz to 30 MHz demodulation bandwidth allows users to accurately analyze complex modulated signals, making it ideal for capturing and decoding various communication formats.

Built on Agilent's exclusive technology, the E4440A integrates the advanced "Digital Signal Processing" capabilities, enhancing its measurement precision and speed. This technology not only improves the analyzer's dynamic range but also allows for quick identification and analysis of signals, ensuring that engineers can optimize performance and troubleshoot issues more effectively.

A unique characteristic of the E4440A is its robust user interface. The spectrum analyzer features a high-resolution display, which provides clear visualizations of signals. Additionally, its intuitive navigation simplifies operation, enabling both seasoned engineers and newcomers to utilize the device effectively without extensive training.

The E4440A is also equipped with a variety of built-in measurement capabilities, including distortion, modulation, and phase noise analysis. These tools empower users to assess the quality of their transmission systems comprehensively, thus facilitating improvements and innovations in design.

In conclusion, Agilent Technologies E4440A stands as a versatile spectrum analyzer that combines cutting-edge technology with user-friendly features. Its broad frequency range, high accuracy, and advanced analysis capabilities make it an essential tool for professionals in the RF and microwave sectors. Whether for research, development, or testing, the E4440A delivers the precision and reliability that engineers expect from Agilent Technologies.