FRYER TROUBLESHOOTING GUIDE (Continued)

PROBLEM

CAUSE

REMEDY

 

 

 

Liquid shortening does

3. Loose knob on thermostat; or thermostat

3. (Continued)

not reach the desired

requires calibration (temperature setting dif-

Recalibrate the thermostat by:

temperature for frying.

fers by about 10°F from measured shorten-

(a) removing the cap on the

(Continued)

ing temperature). (Continued)

thermostat control knob; (b)

 

 

loosening the center brass hex

 

 

nut portion of the knob; (c) turn

 

 

the pointer portion of the knob to

 

 

the measured temperature value

 

 

of the thermostat settings.

 

 

Tighten the brass hex nut to lock

 

 

the adjustment. Replace the

 

 

cap on the knob.

 

4. Thermostat setting is more than 20°F dif-

4. Check the thermostat setting

 

ferent than measured shortening tempera-

against an accurate measure of

 

ture.

the shortening temperature. If

 

 

the temperature difference is

 

 

greater than 20°F, the thermo-

 

 

stat can possibly be recali-

 

 

brated.

 

 

Recalibrate the thermostat by:

 

 

(a) removing the cap on the

 

 

thermostat control knob; (b)

 

 

loosening the center brass hex

 

 

nut portion of the knob; (c) turn

 

 

the pointer portion of the knob

 

 

to the measured temperature.

 

 

Tighten the brass hex nut to lock

 

 

the adjustment. Replace the

 

 

cap on the knob.

 

 

If this calibration is unsuccess-

 

 

ful, the thermostat has failed and

 

 

must be replaced.

 

 

 

Basket does not lower,

1. Electric power circuit breaker not

1. Switch the circuit breaker to

when the timer control

switched ON.

ON.

pushbutton is pressed

2. Electric power cord not plugged into its

2. Plug in the power cord.

after the timer control

receptacle.

 

knob is set to a time

 

 

 

value.

3. POWER Switch not switched ON.

3. Switch the POWER switch ON.

 

4. Loosened wiring connections.

4. Check wiring and tighten all

 

 

connections, especially to the

 

 

basket lifting devices (timer,

 

 

microswitch, and motor).

 

5. Timer has failed.

5. Set a time value using the timer

 

 

control knob; press the push-

 

 

 

23

Image 23
Contents Fryer Contents Models Covered By This Manual Shipping Container Inspection111,000 BTU/Hr Fryer GAS Supply SpecificationsElectrical Grounding Instructions Fryer Electrical SpecificationsCode Requirements Fryer Site Installation RequirementsLEG Installation Instructions Installation RequirementsInstallation Instructions LEG Leveling Instructions Caster Installation InstructionsCaster Leveling Caster Leveling INSTRUC- TionsGAS & Electric Connection Instructions Fryer Restraining Device Installation InstructionsFryer Operating Instructions Fryer Preparation for USE Fryer Operating InstructionsGas Control Valve & Knob Positions Lighting ProcedureShutdown Procedure Recommended Frying Time for Chicken Recommended Frying Time for Popular Fried Foods Anets Daily Cleaning Procedure Daily Cleaning ProcedureMonthly Maintenance Instructions Problem Cause Remedy Fryer Troubleshooting GuideFryer Troubleshooting Guide Pilot Recalibrated Brated Value Fryer Troubleshooting Guide Fryer Troubleshooting Guide Limited Warranty Toll-free Customer & Warranty Service 800

MX-14-2AA, MX-7A, MX-14-2E, MX-14AA, MX-14E specifications

Anetsberger Brothers is renowned in the world of technology for their innovative and high-quality products, among which the MX series stands out. The MX-14-2AA, MX-7E, MX-7A, MX-14AA, and MX-14-2E models are prime examples of their commitment to excellence.

The MX-14-2AA is designed for intense usability with a focus on performance. Its robust construction ensures durability while providing excellent functionality in various environments. This model features an advanced control interface, allowing users to adjust settings with precision. Its energy-efficient design not only minimizes operational costs but also reduces the carbon footprint, showcasing Anetsberger Brothers' commitment to sustainability.

The MX-7E emphasizes versatility and ease of use. It is equipped with a user-friendly control panel that facilitates quick adjustments, making it suitable for both novice and experienced users. The MX-7E also incorporates cutting-edge technology for enhanced productivity, ensuring that tasks are completed swiftly without compromising on quality.

The MX-7A model takes a step further by integrating innovative features that optimize performance. With its superior thermal control system, users can expect consistent results, making it ideal for commercial applications where reliability is paramount. Additionally, the MX-7A incorporates smart technology to monitor usage patterns, providing insights that help in maintaining efficiency and reducing waste.

For those seeking a combination of power and efficiency, the MX-14AA is an outstanding choice. This model boasts high output capabilities, making it ideal for large-scale operations. It is constructed with advanced materials that enhance heat retention, ensuring that it meets the demands of high-traffic environments. Furthermore, the MX-14AA features an intuitive interface that simplifies operation and minimizes training time.

Lastly, the MX-14-2E is engineered for robust performance with a focus on user-friendly design. It comes with dual controls that allow for independent operation, making it perfect for multitasking. The MX-14-2E also benefits from intelligent diagnostic systems that help detect maintenance needs before they become problems, ensuring longevity and reliability.

In summary, the Anetsberger Brothers MX series represents the pinnacle of engineering excellence, combining advanced features with practical usability. Each model is tailored to meet the diverse needs of users while promoting efficiency, sustainability, and ease of operation, making them a valuable addition to any professional setting.