Extron electronic RSU 126, RSF123 Operation, cont’d, Selecting an input using contact closure

Page 18

Operation, cont’d

Selecting an input using contact closure

Use one of the following methods to select an input via contact closure:

Using a contact closure device: If a two- or four-button contact closure device is connected to the SW USB’s Contact port, press the button on the device that corresponds to the SW USB input that you want to select (the first button on the left selects input 1, the second button selects input 2, etc.).

Using a jumper wire: On the Contact port, insert one end of a small piece of wire into the ground (_) port and the other end into the port with the desired input number (1, 2, 3, or 4).

Using an IR 102: Refer to your IR 102 User’s Manual for this procedure.

Selecting an input using SIS commands

You can also select an input via an RS-232 connection, using SIS commands. See chapter 4, “SIS Configuration and Control,” for a list of available SIS commands and their explanations.

If an Extron A/V switcher is connected to the RS-232 Pass Thru port, the SIS commands that you enter can also be passed through to the connected switcher, even if the connected switcher has more inputs than the SW USB (see the next section).

Issuing commands to an Extron A/V switcher via the RS-232 Pass Thru port

You can configure the SW USB to pass commands through the RS-232 Pass Thru port to a connected A/V switcher in the following modes:

Loop 1 mode: SIS commands that are issued to the

SW USB via an RS-232 interface (such as HyperTerminal) on a computer or control system connected to the

SW USB’s RS-232 port can be passed through to an A/V switcher connected to the RS-232 Pass Thru port.

Loop 1 mode is the default mode. If you need to switch the SW USB to this mode, enter the SIS command E1LOOP}.

Loop 0 mode: The input selection SIS command X!! (where X!is the input number) can be issued to the SW USB and the connected A/V switcher via the buttons on the SW USB front panel, contact closure, or the RS-232 interface.

To enable Loop 0 mode, enter the SIS command E0LOOP}.

The following table summarizes the two loop modes:

Mode

SIS commands issued via:

SIS command to enable

 

 

 

Loop 0

Contact closure, front panel,

E0LOOP }

 

or RS-232 interface (Input

 

 

selection SIS command X!! only)

 

 

 

 

Loop 1

RS-232 interface*

E1LOOP }

 

 

 

*See the command/response table in chapter 4, “SIS Configuration and Control,” for an explanation of all supported SIS commands.

SIS command processing in Loop 1 mode

When an A/V switcher is connected to the RS-232 Pass Thru port and Loop 1 mode is enabled, the available SIS commands are processed in one of the following ways:

Passed through to­ the A/V switcher without being acted on by the SW USB

Performed by the SW USB and not passed through to the A/V switcher

Performed by the SW USB and passed to the A/V switcher, which also performs them. This applies only to the input selection command X!!.

The table on the next page shows how the SIS commands are handled by an SW USB with a connected A/V switcher. (Unless otherwise indicated, commands are not case-sensitive.)

3-4

SW USB Series • Operation

SW USB Series • Operation

3-5

Image 18
Contents SW USB Series Precautions Extron’s Warranty安全须知 中文 FCC Class a NoticeQuick Start Guide SW USB Series StepTable of Contents Introduction Table of Contents, cont’dOne SW USB SeriesAbout this Manual FeaturesIntroduction About the SW USB SeriesIntroduction, cont’d Application Diagrams SW4 USBSW USB Series InstallationTwo Introduction, cont’dMounting the SW USB Series Switcher InstallationInstallation Overview Tabletop useInstallation, cont’d Rack mounting procedureFurniture mounting SW2 USB rear panel Rear Panel FeaturesPreparing the SW USB for under-desk mounting SW4 USB rear panelWiring the Power Connector Power connector wiringRS-232 port Installation, cont’d Wiring for RS-232 CommunicationRS-232 connector pin assignments RS-232 Pass Thru portContact Closure Control Connecting Multiple SW USB Switchers in a SystemControlling an Extron A/V switcher in Loop 0 mode Connections for RS-232 loop-throughThree OperationOperation Front Panel FeaturesPowering on the switcher OperationsMode SIS commands issued via SIS command to enable Loop Selecting an input using contact closureSelecting an input using SIS commands SIS command processing in Loop 1 modeSending commands to an A/V switcher using contact closure Enabling front panel lockout executive modeSW USB Function SW USB Response to Host Command Contact closure SIS command sent Function on SelectionSetting up for host emulation ResettingSetting executive mode Host emulation SW4 USB Plus onlyFour SIS Configuration and ControlTroubleshooting Peripheral emulation SW4 USB Plus onlySIS Configuration and Control Host-to-Switcher CommunicationsUsing the Command/Response Table SIS Configuration and Control, cont’d Command/response table for SIS commandsSW USB Series SIS Configuration SIS Configuration and Control, cont’d Updating the Firmware Downloading and installing the Firmware LoaderDownloading and installing the SW USB firmware Loading the firmware to the SW USB using the Firmware Loader Problem solving Specifications, Part Numbers Accessories AAppendix aSpecifications, Part Numbers, Accessories SpecificationsAccessories Optional accessoriesMounting options Specifications, Part Numbers, Accessories, cont’d

SW USB Series, RSB 126, RSU 126, RSB129, RSF123 specifications

Extron Electronic is a well-known brand in the AV industry, renowned for its high-quality signal distribution, control systems, and mounting solutions. Among its impressive range of products, the RSB129, RSF123, RSU 126, RSB 126, and SW USB Series stand out due to their sophisticated features and technologies.

The RSB129 is a robust rack shelf designed to accommodate a variety of equipment, such as routers, switches, and other AV devices. This shelf can support up to 300 pounds, making it an excellent choice for heavy-duty applications. It also features adjustable mounting points that allow for flexible placement of devices, ensuring an organized and efficient setup.

The RSF123, on the other hand, is a flexible rack frame solution that provides a reliable mounting option for intermediate size equipment. This 2U rack frame is built to hold devices securely, while its front ventilation design aids in maintaining optimal temperature levels. The RSF123 is particularly popular for those looking to streamline their installations with a clean and professional aesthetic.

The RSU 126 is another versatile rack mount solution that focuses on aesthetic appeal while providing functionality. Designed for environments where aesthetics matter, the RSU 126 features a smooth, sleek design that integrates seamlessly into office and conference room settings. Its compact 2U size makes it suitable for various AV applications, while its durable build ensures long-lasting use.

The RSB 126 is similar in nature to the RSB129 but is crafted for smaller setups. This 1U rack shelf is ideal for less intensive applications but still boasts impressive weight support. It features a front lip that prevents equipment from sliding off, ensuring that devices are kept securely in place. The RSB 126 is perfect for studios, server rooms, or any location requiring a compact yet sturdy shelf.

Finally, the SW USB Series is a suite of USB products designed to streamline connectivity in modern AV installations. These USB devices offer flexible options for extending USB signals over long distances without loss of quality. They support a variety of USB protocols, making them compatible with numerous devices, from cameras to computers. The SW USB Series aims to simplify complex installations, ensuring a reliable connection in various environments.

In summary, Extron's RSB129, RSF123, RSU 126, RSB 126, and SW USB Series products cater to a variety of AV installation needs, combining durability, functionality, and aesthetics. Whether for heavy-duty rack shelving or streamlined USB connectivity, these products are designed to enhance any AV setup.