Hoshizaki MWH KML-451MAH, MRH, MWH KML-631MAH, KML-250MAH Factory Line Set Installation

Page 26

5. Line Set Installation

Precharged factory line sets, available as optional equipment from Hoshizaki America, are recommended. For details, see "II.G.5.a) Factory Line Set Installation." Field fabricated line sets are allowed. For details, see "II.G.5.b) Field Fabricated Line Set Installation."

a)Factory Line Set Installation

1)Route the factory line set (see "II.G.4 Line Set Size and Refrigerant Charge" for details) from the remote condenser unit to the icemaker. Leave a service loop behind the icemaker to allow the icemaker to be pulled out for service. See Fig. 12. Factory fabricated line sets are precharged and do not need to be evacuated. If the line set is too long or too short, see "II.G.5.a)(1) Factory Line Set Modification."

NOTICE

Ensure that there are no traps and no kinks in the line set. The service loop is not considered an oil trap.

Do not coil extra line set.

2)Connect the refrigerant lines to the appropriate male fittings on the remote condenser unit first and then at the icemaker. Make a proper connection as follows:

a.Remove the protective covers from the male fitting and female coupling.

b.Apply Polyol Ester (POE) refrigerant oil or Parker Super O Lube to the entire male fitting, including Oring, diaphragm, and threads before making the connection.

See Fig. 13. NOTICE! Do not use thread sealant on the fittings. Use POE refrigerant oil or Parker Super O Lube only.

c.Make sure the male fitting and female coupling are properly aligned, then start the connection by hand to ensure that it is not cross threaded.

d.Tighten the connection with a wrench until it is tight. At this point, the nut has covered most of the threads on the male fitting.

e.Mark a reference line on the female coupling and the remote condenser unit or icemaker panel. Using a backup wrench on the back of the female coupling, tighten the six-sided nut of the female coupling an additional 1/6 turn. See Fig. 14.

3)If you lengthened the line set as outlined in "II.G.5.a)(1) Factory Line Set Modification" and it exceeds 66 feet, see "II.G.4. Line Set Size and Refrigerant Charge" for proper charging of the appliance.

(1)Factory Line Set Modification

1)Recover the line set charge through the Schrader access ports on the Parker quick connect couplings and store it in an approved container. Do not discharge the refrigerant into the atmosphere. Remove the extra line set length or add extra tubing. When adding extra tubing, insulate the additional copper tubes separately.

2)Use an electronic leak detector or soap bubbles to check for leaks. Add a trace

of refrigerant to the lines through the Schrader access ports on the Parker quick connect couplings (if using an electronic leak detector), and then raise the pressure using nitrogen gas (140 PSIG). WARNING! Do not use R-404A as a mixture with pressurized air for leak testing.

26

Image 26
Contents KML-631MAH, MWH, MRH Hoshizaki AMERICA, INC Contents Indicates a situation which could result in damage to Important Safety InformationSerious injury Appliance or propertyAdditional Warning for Remote Models KML-351MH Specifications Electrical and Refrigerant DataKML-250MH KML-451MH KML-631MHDimensions/Connections Air-Cooled Models MAH Units mmWater-Cooled Models MWH Units mmRemote Models MRH Remote Condenser Unit URC-9F use with KML-631MRH Location II. Installation and Operating InstructionsChecks Before Installation How to Remove Panels See Fig Setup Dispenser Unit/Ice Storage Bin and Icemaker SetupIntentionally Left Blank Additional Warnings for Remote Models Electrical ConnectionFor All Models  WARNING Water Supply and Drain Connections See Figs through Air-Cooled and Remote Models IcemakerWater-Cooled Models Connection to an Open Drain SystemWater-Cooled Models Connection to a Closed Loop System Water-Cooled Models Model Shown KML-631MWH Installation of Remote Condenser Unit LocationLine Set Size and Refrigerant Charge Checks Before InstallationSetup Line Set Installation Factory Line Set InstallationField Fabricated Line Set Installation Do not USE Thread Sealant Electrical Connection Stacking Remote Condenser Unit Final Checklist Startup Additional Notice for Remote ModelsIII. Maintenance Maintenance ScheduleCleaning and Sanitizing Instructions Cleaning ProcedureSanitizing Procedure Following Cleaning Procedure Page Drain the water tank IV. Preparing the Icemaker for Periods of Non-UseRemove the water from the icemaker water supply line Page Disposal Hoshizaki AMERICA, INC
Related manuals
Manual 28 pages 29.45 Kb Manual 94 pages 41.69 Kb

MWH KML-351MAH, KML-250MAH, MWH KML-631MAH, MWH, MRH specifications

The Hoshizaki KML-250MAH is a premium ice maker renowned for its innovative design and advanced technology, catering to the high-demand needs of commercial establishments. This model combines efficiency, reliability, and superior performance, making it an excellent choice for restaurants, bars, and hotels.

One of the standout features of the KML-250MAH is its high production capacity. This ice maker can produce up to an impressive 265 pounds of crescent ice daily, ensuring your establishment has a consistent supply of ice for beverages and food preservation. The crescent-shaped ice not only allows for optimal cooling but also enhances presentation, making it suitable for a variety of applications.

The KML-250MAH incorporates advanced technologies to promote efficient operation. The unit uses an air-cooled refrigeration system, which ensures better energy efficiency while reducing operational costs. The machine is designed with a dual condensing fan that effectively optimizes airflow, thereby ensuring consistent ice production in different ambient temperatures, which is crucial in varying commercial kitchen environments.

The durability of this model is another key characteristic. Constructed with stainless steel, the KML-250MAH is built to withstand the rigors of daily commercial use while resisting rust and corrosion. The heavy-duty components used in this ice maker enhance its longevity, making it a smart investment for any business.

In addition, the KML-250MAH is designed with user-friendly features, including a built-in cleaning cycle that simplifies maintenance and ensures hygiene. Its ergonomic control panel provides users with easy access to settings and operational status, enhancing the overall user experience.

Another noteworthy aspect of the Hoshizaki KML-250MAH is its reduced water consumption. This ice maker operates using significantly less water compared to competitors, contributing to a lower environmental impact and cost savings over time.

To sum up, the Hoshizaki KML-250MAH stands out with its high production capacity, robust stainless steel construction, efficient air-cooled technology, user-friendly operation, and eco-conscious design. These features make it an ideal choice for businesses seeking a reliable and high-performing ice-making solution that meets the demands of a bustling commercial environment.