2-10. ELECTRICAL REQUIREMENTS OFE-320 SERIES
DRYWALL CONSTRUCTION Secure
To avoid electrical shock, do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded (earthed). Refer to local electrical codes for correct grounding (earthing) procedures or in absence of local codes, with The National Electrical Code, ANSI/NFPA No.
Refer to the table below for supply wiring and fusing.
|
| (Per Well) |
|
Volts | Phase | Kw | Amps |
3 | 14.4 | 40 | |
220/240 | 3 | 14.4 | 40 |
3 | 14.4 | 17 | |
3 | 14.4 | 20 |
To avoid electrical shock, this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded (unearthed) conductors. The main power switch on this appliance does not disconnect all line conductors.
To avoid electrical shock, this fryer must be adequately and safely grounded (earthed). Refer to local electrical codes for correct grounding (earthing) procedures or in absence of local codes, with The National Electrical Code, ANSI/NFPA No.
CE units require a minimum wire size of 6 mm to be wired to the terminal block.
Permanently connected electric fryers with casters must be installed with flexible conduit and a cable restraint, when installed in the United States. See illustration at left. Holes are available in the rear fryer frame for securing the cable restraint to the fryer. The cable restraint does not prevent the fryer from tipping.