TROUBLESHOOTING

TROUBLESHOOTING

TROUBLESHOOTING

Problem

Cause

Solution

 

1.

Circuit breaker is open.

1.

Reset circuit breaker.

 

2.

Poor connection or defective cord

2.

Check and repair.

Generator is running, but no AC

 

set.

 

 

output is available.

3.

Connected device is bad.

3.

Connect another device that is in

 

 

 

 

good condition.

 

4.

Fault in generator.

4.

Contact authorized service facility.

 

 

 

 

 

Generator runs good but bogs

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

2.

Generator is overloaded.

2.

See "Don't Overload Generator".

down when loads are connected.

3.

Shorted generator circuit.

3.

Contact authorized service facility.

 

 

 

 

 

 

 

1.

Fuel valve is in the "Off" position.

1.

Turn fuel valve to the "On"

Generator will not start; or starts

 

 

 

position.

2.

Vent knob in fuel gauge is closed.

2.

Open vent knob in fuel gauge.

and runs rough.

3.

Low oil level.

3.

Fill crankcase to proper level or

 

 

 

 

 

place generator on level surface.

 

 

 

 

 

Generator shuts down during

1.

Out of fuel.

1.

Fill fuel tank.

2.

Low oil level.

2.

Fill crankcase to proper level or

operation.

 

 

 

place generator on level surface.

 

 

 

 

 

 

 

Generator lacks power.

Load is too high.

See "Don't Overload Generator".

 

 

 

 

 