G. Water Supply and Drain Connections

See Fig. 7, 8, or 9

WARNING

1.Water supply and drain connections must be installed in accordance with applicable national, state, and local regulations.

2.Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of this normal temperature range may affect icemaker performance.

3.To prevent damage to equipment, do not operate the icemaker when the water supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the proper water pressure is reached.

A plumbing permit and services of a licensed plumber may be required in some areas.

External filters, strainers, or softeners may be required depending on water quality. Contact your local Hoshizaki distributor for recommendations.

Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.

The icemaker drain line, dispenser unit/storage bin drain line, and watercooled condenser drain line (if applicable) must be run separately.

Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get a good flow. A vented tee connection is also required for proper flow.

Drain lines should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker, dispenser unit/storage bin, and water-cooled condenser (if applicable) and the floor drain.

13

Image 13
Contents KMD-450MAH KMD-450MWH Hoshizaki AMERICA, INC Contents Important Safety Information KMD-450MAH self-contained air-cooled Specifications Nameplate RatingKMD-450MWH water-cooled KMD-450MAH Dimensions/ConnectionsUnit mm KMD-450MWH Checks Before Installation II. Installation and Operating InstructionsHow to Remove Panels See FigLocation SetupBin Control Installation Electrical Connection 83See , 8, or Water Supply and Drain ConnectionsIcemaker KMD-450MAHConnection to an Open Drain System Water-Cooled Condenser if applicableConnection to a Closed Loop System Final Checklist Startup Cleaning and Sanitizing Instructions III. Cleaning and MaintenanceCleaning Procedure Page Sanitizing Procedure Following Cleaning Procedure Stainless Steel Exterior MaintenanceDispenser Unit/Storage Bin and Scoop Air Filters self-contained air-cooled modelRemove the water from the icemaker water supply line Preparing the Icemaker for Long StorageDrain the water tank Page Hoshizaki AMERICA, INC