Hoshizaki KMD-450MWH, KMD-450MAH instruction manual

Page 24

3)Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve.

4)Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve.

5)Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the spring. While holding the valve open, blow out the condenser using the compressed air or carbon dioxide supply until water stops coming out.

6)Close the drain valve(s).

7)Replace the right side panel and front panel in their correct positions.

24

Image 24
Contents KMD-450MAH KMD-450MWH Hoshizaki AMERICA, INC Contents Important Safety Information Specifications Nameplate Rating KMD-450MAH self-contained air-cooledKMD-450MWH water-cooled Dimensions/Connections KMD-450MAHUnit mm KMD-450MWH II. Installation and Operating Instructions Checks Before InstallationHow to Remove Panels See FigSetup LocationBin Control Installation 83 Electrical ConnectionWater Supply and Drain Connections See , 8, orKMD-450MAH IcemakerWater-Cooled Condenser if applicable Connection to an Open Drain SystemConnection to a Closed Loop System Final Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Page Sanitizing Procedure Following Cleaning Procedure Maintenance Stainless Steel ExteriorDispenser Unit/Storage Bin and Scoop Air Filters self-contained air-cooled modelPreparing the Icemaker for Long Storage Remove the water from the icemaker water supply lineDrain the water tank Page Hoshizaki AMERICA, INC