Grindmaster 5512E instruction manual Care & Cleaning, Sanitizing Carburetor and Valve Components

Page 12

Care & Cleaning (cont.)

3.Using medium sized brush (supplied with freezer) clean the bottom of the valve body and the inside of the plunger bore with detergent solution taking care to remove all remaining lubricant (see figure K). Repeat for other side.

Sanitizing Carburetor and Valve Components

1.Re-assemble carburetor assembly installing the two “O” Rings at the bottom of the carb tube.

2.Place the carburetor assembly in the bottom of the hopper.

3.Replace “O” Rings on valve plunger and lay plunger assembly on a clean piece of paper towel.

4.Prepare a minimum of 4 gallons (15 liters) of sanitizing solution (Stera Sheen Green Label or equivalent) following the manufacturer’s instructions.

NOTE: Add 4 ounces of Stera Sheen to 4 gallons (15 liters) of 120° Fahrenheit (50° Centigrade) water to achieve a concentration of 100 parts per million.

5.Dip the medium sized brush (supplied) into the sanitizing solution and sanitize the inside bore of the dispensing valve (see figure L).

6.Place a small amount of sanitary lubricant onto a piece of clean paper toweling (see figure M).

7.Use a clean piece of paper toweling to pick up the small end of the valve plunger assembly. Apply the lubricant on the other piece of paper toweling to the “O” Rings on the valve plunger assembly (see figure N).

8.Slide the valve plunger spring over the small end of the valve plunger

and, using another clean piece of paper toweling, pick up the valve plunger at the outlet end and insert plunger and spring into the valve body (see figure N).

9.Push up on the valve plunger and insert the stainless steel handle (see figure O).

10.Insert the dispensing valve handle retaining pin (see figure P). Repeat procedure for other side.

Sanitizing and Refilling

1.Pour sanitizing solution into the mix storage hopper and allow the solution to fill freezing cylinder. Use a large brush (supplied) to sanitize all hopper surfaces (see figure Q).

2.Turn panel switch to “CLEAN” and allow freezer to run for 20 minutes.

3.Open dispensing valve and drain solution. Allow the auger to push remaining sanitizer out of the freezing cylinder.

4.Place a small amount of sanitary lubricant onto another piece of clean paper toweling (see figure R).

Figure L Sanitize Valve Body

Figure M Lubricate Plunger

Figure N Installing Plunger and Spring

Figure O Insert Valve Handle

Figure P Insert Retaining Pin

Figure Q Sanitize Hopper

Page 12

Crathco® 5512 Manual

 

 

Image 12
Contents Crathco Beverage Freezers Page Operators Safety Precautions InstallationShipment & Transit Removal from Carton and PalletInstalling Your Unit Installation of Concealed Air Filter AccessoryReduce freezer performance Installation of Spinner/Mixer Accessory Kit optional Figure FOperation & Adjustments How to OperateCarburetor Assembly Mix Considerations GeneralOverrun Computing OverrunStandby Switch Product TipsMix Low Function Consistency Control Overview Product TipsProduct Consistency Adjustment Freezing Cylinder Temperature AdjustmentHopper Temperature Adjustment Consistency Control -OverviewCare & Cleaning Daily Cleaning ProcedureCleaning Carburetor, Dispensing Valve and Plunger Assembly Drain and RinseCare & Cleaning Sanitizing Carburetor and Valve ComponentsSanitizing and Refilling Cleaning Following Complete Disassembly of Unit Sanitizing & RefillingReassembly Figure BBMaintenance Suggested Weekly MaintenanceSuggested Monthly Maintenance How to Clean Exposed Filter Sanitizing and RefillingHow to Clean Concealed Filter How to Clean CondenserAnnual Maintenance Disconnect electrical powerBelt Adjustment Figure CCFreezer Specifications Crathco 5512 Manual Troubleshooting Guide Excessive dispensing Valve leakageScraping sound during Clicking soundCrathco 5512 Manual Exploded View Model 5512 Stock Assembly Part Number DescriptionExploded View Model 5512-E Stock Assembly Exploded View Model 5512 Base Assembly Flat WasherExploded View Model 5512-E Base Assembly Exploded View Model 5512 Base Assembly Refrigeration Exploded View Model 5512 Base-E Assembly Refrigeration Exploded View Probe Assembly Probe W0572362Assembly Exploded View Model 5512 Electrical Components Exploded View Model 5512-E Electrical Components Model 5512 Electrical Components Front Electrical Box Model 5512-E Electrical Components Front Electrical Box Model 5512 Contactor Box Model 5512-E Contactor BoxModels 5512 & 5512-E Electrical Box Models 5512 & 5512-E Relay BoxCrathco 5512 Manual Model 5512 Ladder Diagram Model 5512-E Ladder Diagram Model 5512 Wiring Diagram Model 5512-E Wiring Diagram Models 5512 & 5512-E Refrigeration Schematic