Sanitizing and Refilling
1.Prepare a minimum of
NOTE: Add sanitizer to
2.Pour sanitizing solution into the mix storage hopper and allow the solution to fill freezing cylinder. Use a brush to clean the hopper sides and bottom. (Repeat steps 1 & 2 for opposite side.)
3.Turn panel switch to "CLEAN" and allow freezer to run for 5 minutes.
4.Open dispensing valve and drain solution. Turn freezer to "CLEAN" for a few seconds to allow the auger to push remaining sanitizer out of the freezing cylinder.
5.If you are using a concentrated product, mix the product according to the manufacturer's instructions.
6.Open dispensing valve. Pour product into the hopper and allow this product to chase out any remaining sanitizer. Watch the product flowing out of the dispensing valve and close the valve when the new mix has purged the san- itizer remaining in the cylinder.
7.Sanitize and install the carburetor. (Figure R). Refill mix hopper.
8.Turn front panel switch to "ON". Allow approximately 20 to 30 minutes for the freezer to reach proper consistency. Repeat on other side.
Maintenance
! WARNING! Disconnect power for maintenance. Do not attempt to perform maintenance on the freezer until electrical power has been disconnected.
Suggested Weekly Maintenance
1.Clean, lubricate and sanitize the freezer following guidelines in Care and Cleaning on page 11.
2.Clean the exterior of the freezer using a soft wet cloth.
Suggested Monthly Maintenance
How to Clean Exposed Filter:
1.Slide exposed filter out of the rails by pulling forward on the filter. It is recommended to remove the filter by using the palm of your hand and applying even pressure to the face of the filter.
2.Clean filter with liquid soap and water.
3.Soak filter for 15 minutes.
4.Rinse filter with heavy stream of water, opposite the direction of air flow. Allow filter to dry.
5.Slide the filter into the rails until the filter contacts the stop on the top rail.
Crathco® 5512 Manual | Page 15 |
|
|