FREEZE CYCLE IS LONG, LOW ICE PRODUCTION
Problem
•Cause
Water temperature is too high
•Connect to a cold water supply, verify check valves in faucets and other equipment are functioning correctly
Dirty Condenser
•Clean condenser
High air temperature entering condenser
•Air temperature must not exceed 120°F (39°C)
Water inlet valve filter screen is dirty
•Remove the water inlet valve and clean the filter
screen
Water inlet valve stuck open or leaking
•Turn off ice machine, if water continues to enter
ice machine, verify water pressure is ok then replace water inlet valve
Water inlet valve is not working
•Water inlet valve must be replaced
Refrigeration problem
•Refer to refrigeration diagnostics
Water escaping from sump during freeze cycle
•Check standpipe and drain
•Check for water tracking out of water circuit