Grindmaster 67710E To Change the Water Tank Temperature, Timer Adjustment, Flow Rate Adjustment

Page 13
Spray Over Rate Control
Figure 7, Flow Valve

To Change the Water Tank Temperature (cont)

Insert a miniature, flat screwdriver into the center of the shaft.

Turn the screw slightly to make adjustments: clockwise to increase the temperature, counterclockwise to lower.

Turn the power back on and allow the temperature to equalize. The water hot light turns on when the heaters are off.

Check the water temperature inside the tank. Repeat adjustment if needed.

Timer Adjustment

See figure 6.

Two timers control the brew cycle including the air agitation. When a start switch is pressed, the timer sends power to the pump through the normally open contact. Also, the brew light is turned on. These stay on for the set amount of time. After the time is up, the air agitation turns on to stir the coffee.

Timer

Adjust

Figure 6, Brew Timer

The time is set by turning an adjustment potentiometer,

see figure 6. This potentiometer is factory set to spray for 12 1/2 minutes.

To Adjust the Timer:

Turn off power to the urn.

Remove the control enclosure access cover.

Locate the timer you need to adjust.

Find the marked adjustment potentiometer on the front of the timer.

Insert a screwdriver and turn the potentiometer to the approximate time you need.

Restart the brewer and measure the time of a brew - start button pressed to sprayover stop.

Re-adjust the potentiometer to make fine corrections if needed.

Flow Rate Adjustment

See figure 7.

Two valves - one for each liner - control the flow rate of water from the pump to the sprayover. They have been factory set to provide proper rate for a twelve minute brew time. Only adjust these if the rate has obviously come out of adjustment.

To Adjust the Rate:

Turn off all power to the urn.

Remove the control enclosure access cover.

Locate the valve to the liner you want to adjust.

• Open the valve slightly for faster sprayover, close for slower sprayover.

Turn the urn back on and wait for the water hot light to turn on.

Brew water into the liner for the standard 12 1/2 minutes. Adjust the timer if it does not run the pump for the correct time.

 

 

Page 13

American Metal Ware 67710E Coffee Urn

Image 13
Contents Model 67710E American Metal Ware 67710E Coffee Urn Introduction Safety and Security Features of This ModelMaintenance About the 67710E Coffee Urn General DescriptionPre-Installation Package Contents American Metal Ware 67710E Coffee Urn Initial Considerations InstallationElectric Hook-Up Service Hookup LocationsInitial Start Up Start the Brew Load the CoffeeAfter the Brew is Finished Bypass Adjustment AdjustmentsThermostat Adjustment To change the water tank temperatureTimer Adjustment To Change the Water Tank TemperatureFlow Rate Adjustment To Adjust the TimerFill Rate Adjustment To adjust the rateTo Adjust the Fill Rate After Each Use CleaningEach Day Semi-WeeklyAmerican Metal Ware 67710E Coffee Urn American Metal Ware 67710E Coffee Urn American Metal Ware 67710E