It is a 3/8 Female NPT connection. See the
Electric Hook-Up
Before starting any work, be sure the electric line has been turned off. Check the nameplate on the urn for the elec- tric ratings of the urn. A wiring diagram is also provided inside the control enclosure and in this manual. Use the appropriate circuit breaker and cord for the electric service that this urn that requires. Secure the cord to the rear of the control enclosure with the appropriate cord grip bushing. The hole for electric connection is located on the rear of the urn’s control enclosure as shown in figure 1 and on the
Wire the cord to the terminal block and the ground connection shown in figure
2.Be sure the connection is secure and no strands touch adjacent wires.
Electric Inlet
3/8” FPT
Water
Inlet
Figure 1, Service Hookup Locations
Figure 2, Terminal Block
|
|