Graco 310554V Analyzing Causes for a Motor Fault Alarm, Using Automatic Mode

Page 23

Using Automatic Mode

Entering Automatic Mode

To put the PrecisionSwirl module into Automatic mode:

You are about to place the system under robotic control. Make sure dispensing will not endanger people or equipment before proceeding.

1.Make sure the POWER indicator, shown in FIG. 12, is lit at the control assembly. If it is not, turn the MAIN power switch to the ON position, turning on power to the PrecisionSwirl control assembly cir- cuitry.

2.Set the CONTROL SELECT switch to AUTOMATIC.

3.Press the RUN/ENABLE (black) button. Make sure the green RUN indicator, shown in FIG. 12, is lit at the control assembly.

The PrecisionSwirl orbital dispenser is now enabled. When it receives a 24 Volt RUN/ENABLE command from the robot, the PrecisionSwirl orbital dispenser motor starts and reaches full speed in about one sec- ond. The orbital dispenser motor stops when the 24 Volt RUN/ENABLE command is removed.

4.Leave the control assembly in this state during nor- mal operation.

Leaving Automatic Mode

To leave Automatic dispense mode and idle the module:

1.Press the STOP (red) button.

2.Set the CONTROL SELECT switch to MANUAL.

3.Make sure the green RUN indicator, shown in FIG. 12, is off at the control assembly.

Using Manual Mode

1.Make sure the POWER indicator, in FIG. 12, is lit at the control assembly. If it is not, turn the MAIN power switch to the ON position, turning on power to the PrecisionSwirl control assembly circuitry.

2.Set the CONTROL SELECT switch to MANUAL.

PrecisionSwirl Module Operation

The system is now ready to dispense. Make sure dispensing will not endanger people or equipment before proceeding.

3.Press the RUN/ENABLE (black) button. Make sure the green RUN indicator, shown in

FIG. 12, is lit at the control assembly.

The PrecisionSwirl orbital dispenser motor starts imme- diately.

Stop Manual Swirling

To stop manual swirling and idle the module:

1. Press the STOP (red) button.

The PrecisionSwirl orbital dispenser is now disabled and will stop swirling material.

2.Make sure the green RUN indicator, shown in FIG. 12, is off at the control assembly.

Analyzing Causes for a Motor Fault Alarm

Circuitry on the relay board monitors the motor speed to verify that the motor is functioning properly.

When the motor functions improperly, the circuitry on the relay board activates the motor fault alarm. The alarm turns on when:

the motor speed has not risen within the +/-50% tol- erance range within five seconds after startup.

the motor speed is outside the tolerance range for at least five seconds while operating.

When a fault occurs, the motor fault light on the control panel illuminates, and the alarm relay activates sending the fault signal out via the automatic control cable. The alarm remains turned on until the fault condition is cor- rected or the run command is removed.

A fault will also be generated if any of the front panel controls are not in the correct position for automatic operation (power switch, enable switch, manual/auto switch).

310554V

23

Image 23
Contents Orbital Dispenser PrecisionSwirlTool Mount List of ModelsTool Mounted Dispensers Cable AssembliesContents Equipment Misuse Hazard Fire and Explosion Hazard Skin Injection HazardToxic Fluid or Fumes Hazard 310554V Repair and Repacking the Product Unpacking and RepackingUnpacking the Product PrecisionSwirl Capabilities PrecisionSwirl OverviewNo. Description PrecisionSwirl in Basic Robotic SystemElectrocution Hazard Installing the Control AssemblyPreparing to Install the Control Assembly Mounting the Control AssemblyMounting the Control Assembly FIRE, EXPLOSION, and Electric Shock Hazard InstallationGrounding the Control Assembly Description Requirements Connecting the Control Assembly to a Power SourceElectric Shock Hazard PE/GND Mounting the Dispense Valve Installing the Dispense ValveConnecting Air Lines to Dispense Valve Connecting Material Hose to Dispense ValveConnecting the Motor Control Cable Installing Cable AssembliesMotor Control Cable 15 ft Signal Description Connecting the Automatic Control CableGrounding the System Verifying Ground ContinuityVerifying Ground Continuity Inspecting the Orbital DispenserPrecisionSwirl Module Operation Control Assembly Controls Button/Switch What it doesControl Assembly Indicators Button/Switch Light is Meaning Setting Operation Modes Using Automatic Mode Analyzing Causes for a Motor Fault AlarmAdjusting Orbital Dispenser Motor Speed Troubleshooting Problem Cause Solution TroubleshootingControl Assembly Service Main Power Switch Replacement Main Power Switch RemovalPotentiometer Removal Potentiometer Replacement  Panel Assembly ServiceSwirl Control Board Removal Swirl Control Board ReplacementRFI Filter Removal RFI Filter Replacement      Relay Removal Relay ReplacementFuse Removal Fuse ReplacementPart No. Description Qty Control Assembly Parts8037B 13, 15 13, 53 42, 43 No. Part No. Description Qty Part No , PrecisionSwirl Panel AssemblyControl Assembly Parts 310554V Socket Accessory PartsConnection Diagram Motor Control Cable AssembliesMotor Control Cables Part Number Length Description Torsional Motor Control Cable AssembliesDispenser Valve Adapter Fittings Robot Interface Cable AssemblyMotor Controller Wiring, Lines Wiring Diagrams Control Assembly Technical DataGraco Information Graco Standard Warranty

310554V specifications

The Graco 310554V is an advanced airless paint sprayer designed for both professional contractors and DIY enthusiasts looking for a reliable and efficient solution for their painting projects. This sprayer is recognized for its versatility, ease of use, and capability to deliver a high-quality finish with minimal effort.

One of the standout features of the Graco 310554V is its powerful 3000 PSI pump. This high-pressure capability allows users to spray thicker materials and achieve excellent coverage in fewer passes. The pump is also designed with a robust construction, ensuring durability and longevity, making it suitable for heavy-duty use.

Another key characteristic of the Graco 310554V is its SmartControl technology. This innovative feature provides a consistent spray pattern at any speed, which allows users to adjust the flow of paint depending on the specific requirements of the project. Whether spraying a large surface or intricate detail work, SmartControl ensures that the finish remains smooth and even.

The Graco 310554V is equipped with a reversible spray tip that enables users to quickly unclog the nozzle without the need for disassembly. This feature is especially beneficial when working with thicker paints or when the sprayer is not frequently cleaned. The inclusion of the RAC X tip also offers a variety of spray patterns and sizes, giving users more control over the application process.

Portability is another defining feature of the Graco 310554V. It comes with a lightweight design and an integrated handle, allowing for easy transportation between job sites. Additionally, the unit includes a built-in carry handle and a durable frame that enables it to withstand the rigors of regular use.

The Graco 310554V also showcases user-friendly innovations, such as a simple on/off switch and adjustable pressure settings. These features simplify the setup process and empower users to tailor the sprayer's performance based on the material used and the type of job at hand.

Overall, the Graco 310554V combines professional-grade performance with innovative technology, making it an excellent choice for those looking to achieve a flawless finish on their painting projects. Whether you are tackling a small home improvement job or a large-scale professional painting task, this sprayer is engineered to meet varying demands and deliver outstanding results.