Jackson Tempstar S technical manual Ground Lug

Page 16

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS (CONTINUED)

PLUMBING CHECK: Slowly turn on the water supply to the machine after the incoming fill line and the drain line have been installed. Check for any leaks and repair as required. All leaks must be repaired prior to placing the machine in operation.

ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.

Disconnect electrical power supply and place a tag at the disconnect switch to indi- cate that you are working on the circuit.

The dishmachine data plate is located on the right side and to the front of the machine. Refer to the data plate for machine operating requirements, machine volt- age, total amperage load and serial number.

To install the incoming power lines, open the control box. This will require taking a phillipshead screwdriver and removing the four (4) screws on the front cover of the control box. Install 3/4” conduit into the pre-punched holes in the back of the con- trol box. Route power wires and connect to power block and grounding lug. Install the service wires (L1, L2, and L3 (3 phase only)) to the appropriate terminals as they are marked on the terminal block. Install the grounding wire into the lug pro- vided. Tighten the connections. It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.

 

 

 

 

Power Block

 

 

 

 

 

Ground Lug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Incoming Power Connection

VOLTAGE CHECK: Ensure that the power switch is in the OFF position and

apply power to the dishmachine. Check the incoming power at the terminal block and ensure it corresponds to the voltage list- ed on the data plate. If not, contact a qualified service agency to examine the problem. Do not run the dishmachine if the volt- age is too high or too low. Shut off the service breaker and mark it as being for the dishmachine. Advise all proper personnel of any problems and of the location of the service breaker. Replace the control box cover and tighten down the screws.

Tempstar LT/NB/S Technical Manual 7610-003-61-42 B

Issued: 10-08-2008 Revised: N/A

8

Image 16
Contents INSTALLATION/OPERATION Technical Manual Tempstar Tempstar LT Tempstar NBTempstar S Jackson MSC, LLC. P.O. BOX 1060 HWY EPage Manufacturers Warranty ONE Year Limited Parts & Labor WarrantyStop Pare Arret Added new NSF rating Released to productionRemoved NSF Rating from steam heated unit Model Serial No Installation Date Service Rep. Name Phone No Nomenclature for the Models Covered in this ManualTable of Contents VI.C VI.AVII Section Specification Information Specification Information This model is wired in a wye configuration for the heaters Volts Ratings Amps CircuitTempstar S Rinse TypicalDimensions TEMPSTAR/NB/LT/S TOP Mounted Control BOX Drain 1 1/2 NPT 8 12.4 cm 25 1/4 64.1 cmTable Dimensions Corner InstallationSection INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsSide and from front to back before making any connections Ground Lug Operation Instructions Detergent Control False Panel Installation False panel positioned in unitSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting Section Troubleshooting Common ProblemsProblem Doors will not close completely Problem Water leaks at the wash pumpProblem Will not rinse during autocycle Problem Dishes are not coming cleanSection Parts Section TOP Mounted Control BOX Assembly with Universal Timer Parts SectionTimer Bracket Switch, 8 ButtonTimer, Universal Relay, 415V, 3PH, 5 Wire OnlyHood Assembly Bolted Single Support Design Cantilever ARM/DOOR Assemblies 10, 1119, 11 3e3dYoke Assembly Connector, Cantilever ArmMagnet, Reed Switch Door, Right Side Complete AssemblyTUB Assembly Rack Assembly Pump Support Bracket AssemblyConnector, 1/2 90 Tub WeldmentSteam TUB Assembly Connector, 1/2 90 Deg Frame Assembly Front PanelRinse Tank Assembly Rinse Tank and Round Flange Heater Assembly Washer, 1/4 S/S FlatNut, Hex, 1/4-20-18 Washer, 1/4 I.DCoil Assembly 05700-002-08-62 05700-002-08-52Incoming Steam Plumbing Assemblies Model Volts Phase Wash Motor Assembly Wash MotorsMotor & Pump Assembly Other parts not shownModel Volts Phase Wash HEATERS/RINSE HeatersModel Volts Rinse Heaters Round Flanged HeaterTempstar 208 04540-003-58-27 04540-003-58-28 230 Tempstar Incoming PLUMBING/OUTLET Plumbing Assembly Complete AssemblyComplete assembly 05700-003-60-75 Tube Length Chart Item # Length InchesWprk KIT Option Tempstar LT & Tempstar NB Incoming Plumbing Assembly Solenoid Valve & 1/2 NPT Vacuum Breaker Repair Parts Kits Complete Vacuum Breaker Assembly, 1/2 NPTComplete 110 Volt Solenoid Valve Assembly, 1/2 Coil & Housing only1811 Wash & Rinse ARM/MANIFOLD AssembliesRinse Injector Gasket Per machine 05330-111-42-81 Bearing Assembly Rinse Manifold AssemblyUpper Manifold Lockwasher,3/8Other Safety Door Interlock SDI components not shown Transformer05925-111-64-18 380V Transformer 05950-111-64-17False panel positioned in unit Switch, Door, Magnetic Reed Bearing Assembly, Wash ArmSwitch, Power Push Button Pump & Motor Assembly, S/SDrain Quench Assembly To Dishmachine DrainTee, 1-1/2 x 1-1/2 x 1-1/2 Reducer, 1-1/2 to 1/2 To Cold Water SupplyElectrical Schematics For TOP Mount Units Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics For Options SDI Option Exhaust FAN HOOKUP/DRAIN Quench Options Section Jackson Maintenance Repair Centers Jackson Maintenance & Repair Centers Alabama to FloridaService CO Florida to MarylandJackson Service Compa Maryland to NEW YorkCertified Service Center Rons Service NEW York to PennsylvaniaRhode Island to Wisconsin CENTER, INCWisconsin to WYOMING/INTERNATIONAL Jackson Technical Manual Addendum

Tempstar S specifications

The Jackson Tempstar S is a notable name in the realm of industrial heating systems, designed to provide efficient and reliable performance for various applications. Known for its advanced technology and user-friendly features, the Tempstar S stands as a true testament to innovation in heating solutions.

At the core of the Jackson Tempstar S is its powerful heating capacity. This unit can efficiently deliver substantial heat output, making it suitable for large-scale operations. It employs a high-performance burner system that ensures optimal combustion efficiency, translating into reduced fuel consumption and lower operating costs. This energy efficiency is enhanced by advanced control systems that allow for precise temperature regulation.

One of the standout technologies integrated into the Jackson Tempstar S is its advanced control interface. Featuring an intuitive digital display, users can easily monitor and adjust settings. This allows for real-time data feedback, increasing overall usability and operational efficiency. Moreover, the system is designed to offer multiple programmable settings, accommodating a range of operational requirements. This versatility is complemented by robust safety features, including overheat protection and flame monitoring, ensuring that the unit operates safely under various conditions.

Another noteworthy characteristic of the Jackson Tempstar S is its construction. Built with durable materials, the unit is designed to withstand harsh industrial environments. Its compact design allows for easy installation and efficient space utilization, making it a practical choice for facilities with limited space. Additionally, the unit is relatively lightweight, facilitating mobility and ease of repositioning when necessary.

Maintenance is simplified with the Jackson Tempstar S. The design focuses on reducing downtime through easy access to key components, making routine checks and service tasks straightforward. This feature is crucial for industries that rely on continuous operation and cannot afford prolonged interruptions.

Additionally, the Jackson Tempstar S prioritizes eco-friendliness. It adheres to strict emissions standards, contributing to a greener operational footprint without sacrificing performance. This commitment to sustainability reflects the growing emphasis on environmentally conscious manufacturing processes in the industrial sector.

In conclusion, the Jackson Tempstar S offers an impressive combination of efficiency, safety, and ease of use. With its robust features, cutting-edge technology, and durability, it stands as a premier choice for industrial heating applications.