Jackson Tempstar S technical manual Motor & Pump Assembly, Other parts not shown

Page 41

SECTION 5: PARTS SECTION

MOTOR & PUMP ASSEMBLY

Complete Pump & Motor Assembly, 60HZ

Complete Pump & Motor Assembly, 50HZ

 

06105-002-69-78

06105-002-19-87

Motor Only, 60HZ

Pump Only Assembly, 60HZ

Pump Only Assembly, 50HZ

06105-002-79-61

 

(Area indicated within box, Casing is included)

(Area indicated within box, Casing is included)

Motor Only, 50HZ

05700-002-79-51

05700-002-85-38

06105-002-85-36

 

Pump Casing (Not shown), 50HZ

 

 

05700-002-41-50

 

 

 

 

Shim Kit, 60HZ

05700-002-82-58

Case Capscrew, 60HZ

05305-002-81-88

Pump Casing 60HZ

05700-002-85-01

 

 

Mechanical Seal, 60HZ

 

 

05330-002-34-22

 

 

Seal, 50HZ

 

 

05330-002-06-21

 

Case O-Ring, 60HZ

 

 

05330-002-81-83

 

 

Seal Plate, 60HZ

Other parts not shown.

 

05700-002-81-87

 

 

Impeller Assembly, 60HZ

Gasket, 50HZ

Drain Plug, 60HZ

04730-002-81-89

05700-002-81-86

05330-002-41-48

 

Bracket, 50HZ

Impeller Assembly, 50HZ05700-002-06-22

05700-002-41-49

Shaft Adapter, 50HZ

05700-011-95-49

Tempstar LT/NB/S Technical Manual 7610-003-61-42 B

Issued: 10-08-2008 Revised: N/A

33

Image 41
Contents Tempstar Tempstar LT Tempstar NB INSTALLATION/OPERATION Technical ManualTempstar S Jackson MSC, LLC. P.O. BOX 1060 HWY EPage ONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Removed NSF Rating from steam heated unit Released to productionAdded new NSF rating Nomenclature for the Models Covered in this Manual Model Serial No Installation Date Service Rep. Name Phone NoTable of Contents VII VI.AVI.C Section Specification Information Specification Information Volts Ratings Amps Circuit This model is wired in a wye configuration for the heatersTempstar S Rinse TypicalDrain 1 1/2 NPT 8 12.4 cm 25 1/4 64.1 cm Dimensions TEMPSTAR/NB/LT/S TOP Mounted Control BOXCorner Installation Table DimensionsSection INSTALLATION/OPERATION Instructions Side and from front to back before making any connections INSTALLATION/OPERATION InstructionsInstallation Instructions Ground Lug Operation Instructions Detergent Control False panel positioned in unit False Panel InstallationSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting Section Common Problems TroubleshootingProblem Water leaks at the wash pump Problem Doors will not close completelyProblem Will not rinse during autocycle Problem Dishes are not coming cleanSection Parts Section Parts Section TOP Mounted Control BOX Assembly with Universal TimerSwitch, 8 Button Timer BracketTimer, Universal Relay, 415V, 3PH, 5 Wire OnlyHood Assembly Bolted Single Support Design 10, 11 Cantilever ARM/DOOR Assemblies19, 11 3e3dConnector, Cantilever Arm Yoke AssemblyMagnet, Reed Switch Door, Right Side Complete AssemblyTUB Assembly Pump Support Bracket Assembly Rack AssemblyConnector, 1/2 90 Tub WeldmentSteam TUB Assembly Connector, 1/2 90 Deg Front Panel Frame AssemblyRinse Tank Assembly Washer, 1/4 S/S Flat Rinse Tank and Round Flange Heater AssemblyNut, Hex, 1/4-20-18 Washer, 1/4 I.D05700-002-08-62 05700-002-08-52 Coil AssemblyIncoming Steam Plumbing Assemblies Wash Motors Model Volts Phase Wash Motor AssemblyOther parts not shown Motor & Pump AssemblyWash HEATERS/RINSE Heaters Model Volts PhaseTempstar 208 04540-003-58-27 04540-003-58-28 230 Rinse Heaters Round Flanged HeaterModel Volts Complete Assembly Tempstar Incoming PLUMBING/OUTLET Plumbing AssemblyComplete assembly 05700-003-60-75 Tube Length Chart Item # Length InchesWprk KIT Option Tempstar LT & Tempstar NB Incoming Plumbing Assembly Complete Vacuum Breaker Assembly, 1/2 NPT Solenoid Valve & 1/2 NPT Vacuum Breaker Repair Parts KitsComplete 110 Volt Solenoid Valve Assembly, 1/2 Coil & Housing onlyRinse Injector Gasket Per machine 05330-111-42-81 Wash & Rinse ARM/MANIFOLD Assemblies1811 Rinse Manifold Assembly Bearing AssemblyUpper Manifold Lockwasher,3/8Transformer Other Safety Door Interlock SDI components not shown05925-111-64-18 380V Transformer 05950-111-64-17False panel positioned in unit Bearing Assembly, Wash Arm Switch, Door, Magnetic ReedSwitch, Power Push Button Pump & Motor Assembly, S/STo Dishmachine Drain Drain Quench AssemblyTee, 1-1/2 x 1-1/2 x 1-1/2 Reducer, 1-1/2 to 1/2 To Cold Water SupplyElectrical Schematics For TOP Mount Units Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics For Options SDI Option Exhaust FAN HOOKUP/DRAIN Quench Options Section Jackson Maintenance Repair Centers Alabama to Florida Jackson Maintenance & Repair CentersFlorida to Maryland Service COMaryland to NEW York Jackson Service CompaNEW York to Pennsylvania Certified Service Center Rons ServiceCENTER, INC Rhode Island to WisconsinWisconsin to WYOMING/INTERNATIONAL Jackson Technical Manual Addendum

Tempstar S specifications

The Jackson Tempstar S is a notable name in the realm of industrial heating systems, designed to provide efficient and reliable performance for various applications. Known for its advanced technology and user-friendly features, the Tempstar S stands as a true testament to innovation in heating solutions.

At the core of the Jackson Tempstar S is its powerful heating capacity. This unit can efficiently deliver substantial heat output, making it suitable for large-scale operations. It employs a high-performance burner system that ensures optimal combustion efficiency, translating into reduced fuel consumption and lower operating costs. This energy efficiency is enhanced by advanced control systems that allow for precise temperature regulation.

One of the standout technologies integrated into the Jackson Tempstar S is its advanced control interface. Featuring an intuitive digital display, users can easily monitor and adjust settings. This allows for real-time data feedback, increasing overall usability and operational efficiency. Moreover, the system is designed to offer multiple programmable settings, accommodating a range of operational requirements. This versatility is complemented by robust safety features, including overheat protection and flame monitoring, ensuring that the unit operates safely under various conditions.

Another noteworthy characteristic of the Jackson Tempstar S is its construction. Built with durable materials, the unit is designed to withstand harsh industrial environments. Its compact design allows for easy installation and efficient space utilization, making it a practical choice for facilities with limited space. Additionally, the unit is relatively lightweight, facilitating mobility and ease of repositioning when necessary.

Maintenance is simplified with the Jackson Tempstar S. The design focuses on reducing downtime through easy access to key components, making routine checks and service tasks straightforward. This feature is crucial for industries that rely on continuous operation and cannot afford prolonged interruptions.

Additionally, the Jackson Tempstar S prioritizes eco-friendliness. It adheres to strict emissions standards, contributing to a greener operational footprint without sacrificing performance. This commitment to sustainability reflects the growing emphasis on environmentally conscious manufacturing processes in the industrial sector.

In conclusion, the Jackson Tempstar S offers an impressive combination of efficiency, safety, and ease of use. With its robust features, cutting-edge technology, and durability, it stands as a premier choice for industrial heating applications.