Jackson Avenger HT, Avenger LT technical manual Operation Instructions /DELIMING Instructions

Page 19

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS (CONTINUED)/DELIMING INSTRUCTIONS

SHUTDOWN AND CLEANING: At the end of the workday, close the door. Start a cycle. Wait approximately five seconds after the green cycle light comes on and then push the POWER OFF switch. This will put the machine in shutdown mode which will let the machine drain completely prior to shutting off. Once the wash tub is drained and power light is off, remove he pan strain- er. Remove soil and debris from the strainer and set to the side. Unscrew the wash and rinse arms from their manifolds. Remove the endcaps and flush the arms with water. Use a brush to clean out the inside of the arms. If the nozzles appear to be clogged, use a toothpick to remove the obstruction. Wipe the inside of the unit out, removing all soil and scraps. Reassemble the wash and rinse arms and replace them in the unit. The arms only need to be hand tight, do not use tools to tighten them down. Reinstall the strainer and close the door.

DELIMING OPERATIONS: In order to maintain the dishmachine at its optimum performance level, it will be required to remove lime and corrosion deposits on a frequent basis. A deliming solution should be available from your detergent supplier. Read and follow all instructions on the label of the deliming solution.

NOTE: If this machine is equipped with a HTS-11, scale prevention and corrosion control device, and lime is becoming a fre- quent problem, the cartridge needs to be replaced. To order a replacement cartridge, call Jackson immediately to have one shipped to you.

To proceed with the deliming operation, fill the dishmachine and add the correct amount of deliming solution as recommended by the deliming solution manufacturer. The water capacity of the tank can be verified on the specification sheet(s) of this man- ual.

Perform the following operations to delime the dishmachine:

1.Push Manual Switch on the front of the control panel. 2.Close the door (after adding the deliming solution).

3.Run the machine for the recommended period of time.

4.Press the Power Switch to turn the unit off and open the door.

5.Wait five minutes, then inspect the inside of the machine. If the machine is not delimed, run another time cycle as per the deliming solution’s instructions.

6.When clean, drain and re-fill the machine.

7.Run in MANUAL for 10 minutes to remove residual deliming solution.

8.Drain and re-fill the machine.

Avenger™ Series Technical Manual 7610-003-34-01 Rev. A

Issued: 05-02-2007 Revised: N/A

13

Image 19
Contents For Jackson Models INSTALLATION/OPERATION Technical ManualONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Revision Date Made Applicable By ECN Details Nomenclature for the Models Covered in this Manual Model Serial No Installation Date Service Rep. Name Phone NoTable of Contents Section Specification Information Specification Information AvengerLT Specifications of the AvengerltTemperatures Electrical Requirements Operating Cycle Seconds Wash TimeAvengerHT Dimensions AvengerLT Dimensions Section INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsWater Supply Connection for Machines with a Water Hardness Electrical Installation Instructions To Prepare Chemical Feeder Pumps for Operation Chemical Dispensing EquipmentPriming Chemical Feeder Pumps Avenger HT Avenger LT Detergent Control Operation Instructions Operation Instructions /DELIMING Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Problem Wash motor doesn’t operate on manual wash Troubleshooting SectionCommon Problems Problem Water overflow from bottom of doorProblem No indication of pressure Problem Rinse water not at required temperature rangeSection Parts Section Control Panel Weldment Assemblies Parts SectionMfg. No Control Panel ASSEMBLY/KICK Panel Weldment AvengerhtComplete Control Panel Assembly QTY DescriptionControl Panel ASSEMBLY/KICK Panel Weldment Avengerlt Terminal Block BOX Assembly Complete Chemical Feeder Pump Assembly 05700-003-32-03 Chemical Feeder Pump Assembly AvengerhtChemical Feeder Pump Assembly Avengerht QTY Description Complete Chemical Feeder Pump Assembly 05700-003-33-32 Chemical Feeder Pump Assembly AvengerltChemical Feeder Pump Assembly Avengerlt QTY Description Chemical Feeder Pump Components Complete Incoming Plumbing Assembly 05700-003-36-32 Vacuum Plumbing Assembly 05700-003-32-14Plumbing Assemblies Avengerht Plumbing Assemblies Avengerlt Plumbing AssemblyComplete Incoming Complete 220 Volt Solenoid Valve Assembly, 1/2 Complete Vacuum Breaker Assembly, 1/2 NPTComplete 110 Volt Solenoid Valve Assembly, 1/2 Coil & Housing only, 1/2 05700-002-64-67Area within this box is an overall Wash MOTOR/DRAIN PLUMBING/ Avengerlt Wash Manifold AssemblyHub, Discharge Machined AvengerHT Shown Other parts not shown Motor & Pump AssemblyRinse ARM & Wash ARM Assemblies Wash Arm Assembly 2 per AvengerLT 1 per AvengerHTComplete Rinse Tank Assembly Avengerht Only 05700-003-31-94 Thermostat & Rinse Tank AssemblyComplete Door Assembly 05700-003-32-09 Door AssemblyDoor Assembly QTY Description Miscellaneous Door Components Frame & Panel Components Miscellaneous Parts Stands & Components Stand AssemblyHTS-11 Scale Prevention & Corrosion Control Device GO BOX KIT Section Electrical Schematics AvengerHT 208-230 Volt 60 Hertz Single Phase Electrical SchematicsAvengerLT 115 Volt 60 Hertz Single Phase Section Jackson Maintenance Repair Centers Alabama to Florida Jackson Maintenance & Repair CentersFlorida to Maryland Service COMaryland to NEW York Jackson Service CompaNEW York to Pennsylvania Certified Service Center Rons ServiceCENTER, INC Rhode Island to WisconsinWisconsin to WYOMING/INTERNATIONAL
Related manuals
Manual 2 pages 9.06 Kb Manual 2 pages 17.61 Kb

Avenger HT, Avenger LT specifications

The Jackson Avenger HT and Avenger LT are two outstanding models in the Jackson line of guitars renowned for their exceptional playability, tonal versatility, and innovative features. Both models cater to a wide range of playing styles, from rock and metal to blues and jazz, making them suitable instruments for musicians at any level.

The Avenger HT is designed for those who seek the aggressive tonal characteristics and performance features typically associated with hard rock and metal genres. One of its standout features is the high-output humbucker pickups that deliver a powerful, punchy sound while maintaining clarity and responsiveness. Coupling these pickups with an ergonomic body shape ensures comfort during extended playing sessions, allowing artists to perform confidently.

In contrast, the Avenger LT emphasizes a lighter design while maintaining a robust tone and superior playability. This model incorporates a unique combination of tonewoods, which optimizes resonance and sustain. The lightweight body eases the burden of long performances, making it a favorite among players who prioritize comfort without sacrificing sound quality.

Both the HT and LT models feature advanced technologies such as locking tuners, which provide tuning stability and facilitate quick string changes. This feature is especially appreciated by performing musicians who need to maintain pitch accuracy throughout a set. Additionally, each model boasts a modern neck profile designed for speed and ease of play, perfect for intricate solos and swift chord changes.

Another remarkable aspect of the Avenger series is the use of high-quality finishes that not only enhance the aesthetic appeal but also provide added durability. Each guitar is crafted with meticulous attention to detail, resulting in a striking, professional-grade instrument that stands the test of time.

For those seeking versatility, the Avenger HT and LT come equipped with various control options, including coil-splitting capabilities. This allows players to switch between humbucker and single-coil sounds, opening up a world of tonal possibilities with a simple flick of a switch.

In summary, the Jackson Avenger HT and LT guitars stand out for their exceptional craftsmanship, innovative features, and versatile playability. Whether you prefer the heavier sound and feel of the HT or the lightweight comfort of the LT, both models offer musicians the tools they need to excel in their musical endeavors. With their striking designs, advanced technology, and affordability, these guitars are a worthy addition to any player's collection.