Jackson Avenger LT, Avenger HT technical manual Specification Information

Page 8

SECTION 1: SPECIFICATION INFORMATION

SPECIFICATIONS of the AVENGERHT

PERFORMANCE/CAPABILITIES

OPERATING CAPACITY (RACKS/HOUR)

RACKS PER HOUR

DISHES PER HOUR

GLASSES PER HOUR

OPERATING CYCLE (SECONDS)

WASH TIME

DRAIN TIME

RINSE TIME

TOTAL CYCLE TIME (MINUTES)

ELECTRICAL REQUIREMENTS

WASH MOTOR HP

3/4

30

NOTE: Typical Electrical Circuit is based upon (1) 125% of the

600full amperage load of the machine and (2) typical fixed-trip cir-

600cuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is dis-

 

played here. Always verify with your electrical service con-

 

tractor that your circuit protection is adequate and meets all

 

applicable national and local codes. These numbers are pro-

82

vided in this manual simply for reference and may change

28

without notice at any given time.

 

10

AvengerHT:

2

 

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

5 MINUTE TIMER OPERATING CYCLE (SECONDS)

VOLTS PH

HZ

RATINGS

AMPS

CIRCUIT

 

 

 

 

 

WASH TIME

DRAIN TIME

RINSE TIME

TOTAL CYCLE TIME (MINUTES)

TANK CAPACITY (LITERS) (GALLONS)

262

208

1

60

8.2KW @ 230V

39 A

50 AMP

230

1

60

8.2KW @ 230V

42 A

60 AMP

 

28

 

 

 

 

 

 

10

NOTE: Always refer to the machine data plate for specific

 

electrical and water requirements. The material provided on

5

this page is for reference only and may be subject to change

 

 

without notice.

WASH TANK

(4.2) 1.1

RINSE TANK

(11.4)

3

TEMPERATURES

 

 

WASH--- (MINIMUM)

(65.6°C)

150°F

RINSE---(MINIMUM)

(82.2°C) 180°F

WATER REQUIREMENTS

 

 

INLET TEMPERATURE (MINIMUM)*

(43.3°C) 110°F

INLET TEMPERATURE (RECOMMENDED)

(60°C) 140°F

WATER LINE SIZE I.P.S. (MINIMUM)

 

1/2”

DRAIN LINE SIZE I.P.S. (MINIMUM)

 

1 1/2”

FLOW PRESSURE P.S.I.

 

20 ±5

*In some cases, this may automatically extend the wash cycle time.

Avenger™ Series Technical Manual 7610-003-34-01 Rev. A

Issued: 05-02-2007 Revised: N/A

2

Image 8
Contents INSTALLATION/OPERATION Technical Manual For Jackson ModelsManufacturers Warranty ONE Year Limited Parts & Labor WarrantyStop Pare Arret Revision Date Made Applicable By ECN Details Model Serial No Installation Date Service Rep. Name Phone No Nomenclature for the Models Covered in this ManualTable of Contents Section Specification Information Specification Information Specifications of the Avengerlt Temperatures Electrical RequirementsOperating Cycle Seconds Wash Time AvengerLTAvengerHT Dimensions AvengerLT Dimensions Section INSTALLATION/OPERATION Instructions Water Supply Connection for Machines with a Water Hardness INSTALLATION/OPERATION InstructionsInstallation Instructions Electrical Installation Instructions Priming Chemical Feeder Pumps Chemical Dispensing EquipmentTo Prepare Chemical Feeder Pumps for Operation Avenger HT Avenger LT Detergent Control Operation Instructions Operation Instructions /DELIMING Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Troubleshooting Section Common ProblemsProblem Water overflow from bottom of door Problem Wash motor doesn’t operate on manual washProblem Rinse water not at required temperature range Problem No indication of pressureSection Parts Section Parts Section Control Panel Weldment AssembliesControl Panel ASSEMBLY/KICK Panel Weldment Avengerht Complete Control Panel AssemblyQTY Description Mfg. NoControl Panel ASSEMBLY/KICK Panel Weldment Avengerlt Terminal Block BOX Assembly Chemical Feeder Pump Assembly Avengerht Complete Chemical Feeder Pump Assembly 05700-003-32-03Chemical Feeder Pump Assembly Avengerht QTY Description Chemical Feeder Pump Assembly Avengerlt Complete Chemical Feeder Pump Assembly 05700-003-33-32Chemical Feeder Pump Assembly Avengerlt QTY Description Chemical Feeder Pump Components Plumbing Assemblies Avengerht Vacuum Plumbing Assembly 05700-003-32-14Complete Incoming Plumbing Assembly 05700-003-36-32 Complete Incoming Plumbing AssemblyPlumbing Assemblies Avengerlt Complete Vacuum Breaker Assembly, 1/2 NPT Complete 110 Volt Solenoid Valve Assembly, 1/2Coil & Housing only, 1/2 05700-002-64-67 Complete 220 Volt Solenoid Valve Assembly, 1/2Wash MOTOR/DRAIN PLUMBING/ Avengerlt Wash Manifold Assembly Area within this box is an overallHub, Discharge Machined AvengerHT Shown Motor & Pump Assembly Other parts not shownWash Arm Assembly 2 per AvengerLT 1 per AvengerHT Rinse ARM & Wash ARM AssembliesThermostat & Rinse Tank Assembly Complete Rinse Tank Assembly Avengerht Only 05700-003-31-94Door Assembly Complete Door Assembly 05700-003-32-09Door Assembly QTY Description Miscellaneous Door Components Frame & Panel Components Miscellaneous Parts Stand Assembly Stands & ComponentsHTS-11 Scale Prevention & Corrosion Control Device GO BOX KIT Section Electrical Schematics Electrical Schematics AvengerHT 208-230 Volt 60 Hertz Single PhaseAvengerLT 115 Volt 60 Hertz Single Phase Section Jackson Maintenance Repair Centers Jackson Maintenance & Repair Centers Alabama to FloridaService CO Florida to MarylandJackson Service Compa Maryland to NEW YorkCertified Service Center Rons Service NEW York to PennsylvaniaRhode Island to Wisconsin CENTER, INCWisconsin to WYOMING/INTERNATIONAL
Related manuals
Manual 2 pages 9.06 Kb Manual 2 pages 17.61 Kb

Avenger HT, Avenger LT specifications

The Jackson Avenger HT and Avenger LT are two outstanding models in the Jackson line of guitars renowned for their exceptional playability, tonal versatility, and innovative features. Both models cater to a wide range of playing styles, from rock and metal to blues and jazz, making them suitable instruments for musicians at any level.

The Avenger HT is designed for those who seek the aggressive tonal characteristics and performance features typically associated with hard rock and metal genres. One of its standout features is the high-output humbucker pickups that deliver a powerful, punchy sound while maintaining clarity and responsiveness. Coupling these pickups with an ergonomic body shape ensures comfort during extended playing sessions, allowing artists to perform confidently.

In contrast, the Avenger LT emphasizes a lighter design while maintaining a robust tone and superior playability. This model incorporates a unique combination of tonewoods, which optimizes resonance and sustain. The lightweight body eases the burden of long performances, making it a favorite among players who prioritize comfort without sacrificing sound quality.

Both the HT and LT models feature advanced technologies such as locking tuners, which provide tuning stability and facilitate quick string changes. This feature is especially appreciated by performing musicians who need to maintain pitch accuracy throughout a set. Additionally, each model boasts a modern neck profile designed for speed and ease of play, perfect for intricate solos and swift chord changes.

Another remarkable aspect of the Avenger series is the use of high-quality finishes that not only enhance the aesthetic appeal but also provide added durability. Each guitar is crafted with meticulous attention to detail, resulting in a striking, professional-grade instrument that stands the test of time.

For those seeking versatility, the Avenger HT and LT come equipped with various control options, including coil-splitting capabilities. This allows players to switch between humbucker and single-coil sounds, opening up a world of tonal possibilities with a simple flick of a switch.

In summary, the Jackson Avenger HT and LT guitars stand out for their exceptional craftsmanship, innovative features, and versatile playability. Whether you prefer the heavier sound and feel of the HT or the lightweight comfort of the LT, both models offer musicians the tools they need to excel in their musical endeavors. With their striking designs, advanced technology, and affordability, these guitars are a worthy addition to any player's collection.