OPERATING INSTRUCTIONS
ICEMAKER OPERATING INSTRUCTIONS
A temperature sensing bulb located in the storage hopper starts and stops the icemaking process (compressor) in response to the ice level in the hopper. With this ice level control “calling”for ice (hopper ice level is low), the total cycle timer energized. This timer , in turn energizes the harvest and agitation timers for their respective “on”times. The chart below details this sequence of events:
|
|
| HARVEST CYCLE | |
|
|
|
| |
|
| Cam |
| |
| Time | Switch | Action | |
|
|
| ||
|
|
| ||
0 | #1 | Timer motor energized. | ||
|
|
| ||
1 | #4 | Water dump valve open. | ||
± | 1 Second | |||
|
| |||
|
|
| ||
1 | #2 | Hot gas solenoid valve open. Air pump off. Condenser fan motor | ||
± | 2 Seconds | off. | ||
| ||||
|
|
|
| |
35 | #2 | Air pump one. Condenser fan motor on. Hot gas solenoid valve | ||
closed. | ||||
|
|
| ||
|
|
|
| |
34 | #3 | Harvest motor on. | ||
|
|
|
| |
40 | #5 |
| ||
(Double set | Hopper agitator motor operated. | |||
47 | ||||
of cams) |
| |||
|
|
| ||
|
|
|
|
When ice contacts the ice level control bulb in the storage hopper, the control will shut down the refrigeration system. If this signal occurs during the harvest cycle, the harvest cycle will be completed before shutdown oc- curs.
To dispense ice, push the lever located on the lower front panel. Ice will flow from the ice chute until the lever is released.
For units with a
90846 | 10 |