2.Remove cold plate cover by loosening thumbscrew on the ice drop chute and lowering chute from plastic drop tube. then, remove cover by lifting slightly in front and slide forward.

3.Wash down the inside of the cold plate, tray and cover with mild detergent solution and rinse. A small, long- handled brush will be found helpful in reaching the corners.

4.Replace the cover, taking care that it is securely positioned in cold plate tray.

5.Replace ice drop chute.

6.Replace the lower front panel, carefully feeding the tubing and wires into the cabinet. Be sure not to pinch any tubing or wires between the panel and cabinet.

Beverage System

1.Remove faucet spouts, wash in mild detergent, rinse and replace.

2.Disconnect electrical power to the carbonator. Shut off the water supply and close the CO2 regulator to the carbonator.

3.Disconnect the syrup tanks from the system.

4.Energize the beverage faucets to purge the remaining soda water in the system.

5.Use a clean 5 gallon tank for each of the following:

A.Cleaning Tank - Fill with hot 120° - 140° F) potable water.

B.Sanitation Tank - Fill with a chlorine sanitizing solution in the strength of 1 ounce of household bleach (sodium hypochlorite) to 2 gallons cold (ambient) potable water (200 PPM).

6.Repeat the following procedure on each of the unit’s syrup product lines:

A.Connect the cleaning tank to the syrup line to be sanitized and to the CO2 system.

B.Energize the beverage faucet until the liquid dispensed is free of any syrup.

C.Disconnect the cleaning tank and hook up the sanitizing tank to the syrup line and CO2 system.

D.Energize the beverage faucet until the chlorine sanitizing solution is dispensed through the faucet. Flush at least two (2) cups of liquid to insure that the sanitizing solution has filled the entire length of the syrup line. Allow solution to set in line for twenty (20) minutes.

E.Disconnect the sanitizing tank. Hook up the product tank to the syrup line and to the CO2 system.

F.Energize the faucet to flush the sanitizing solution from the syrup line and faucet. Continue to draw on faucet until only syrup is dispensed.

7.Repeat Step 2 in reverse order to turn on the carbonator. Dispense at least (1) cup of beverage from each faucet. Check taste. Continue to flush, if needed, to obtain a satisfactory tasting drink.

90846

16

Image 20
Contents M O R a N D U M From kentSpiral ICEMAKER-DISPENSER Table of Contents Table of Contents cont’d Safety Precautions Important Installation NoticeDescription UnpackingPlumbing InstallationLocation Installation Beverage System15 7/8 29/32 29 1/4 18 3/4 Mounting Template Model SID650--8028 3/4 14 7/8 15 3/4 17 5/8 29 1/4 34 3/8 34 7/8 16 5/8 16 1/411 1/8 13/16Models Post MIX Beverage Syustem Schematic BC Models Post MIX Beverage System Schematic Start UP IcemakerIcemaker Operating Instructions Cam Time Switch ActionOperating Instructions Wiring Schematic 115 / 1 / 60 HZ Wiring Diagram Refrigeration Schematic Maintenance Cleaning InstructionsFor Units with Beverage System Dispenser SectionBeverage System MAINTENANCE/ADJUSTMENT Procedure Thermostat Altitude AdjustmentsICE Thickness Adjustment Clearing Evaporator FREEZE-UPHarvest Timer Adjustment Cleaning / Replacing the FilterCleaning the Condenser AIR-COOLED Unit Manual Filling Detail of CAM Wheel # T1 Troubleshooting Guide 90846 90846 RUN? GO to Is ICE Production Icemaker Inoperative YES RUN RUN/STOP Check Voltage Problems No ICE on Evaporator Harvest YES ±10%? CON’T Check Refrigeration System 90846 Dispenser Problem YES Does Agitator ROTATE? 90846 Refrigeration Components Parts ListElectrical Controls Miscellaneous Components Description Refrigeration Components cont’dEvaporator Components Warranty IMI Cornelius INC