Everpure 80, SID650A manual 90846

Page 27

1. TOTALLY INOPERATIVE

YES

POWER

NO

PRESENT AT

 

RECEPTACLE

 

 

 

 

 

 

 

CHECK OR LOOSE CONNECTION

OR BROKEN WIRE INSIDE UNIT

IS LINE

VOLTAGE

NOWITHIN ¦ 10% OF

NAMEPLATE

VOLTAGE?

YES

1.CHECK FOR SHORT CIRCUIT IN WIRING INSIDE UNIT.

2.CHECK COMPONENTS FOR SHORT CIRCUIT OR GROUNDED WIRING.

IS

LINE VOLTAGE LOW

HIGH OR

LOW

 

IS

YES

SUPPLY FUSE

 

BLOWN (OR C/B

 

TRIPPED)?

 

NO

 

CHECK FOR LOOSE CONNECTION

 

OR BROKEN WIRE IN SUPPLY

 

WIRING TO UNIT.

IS

YESFUSE OR C/B

SIZE PROPER

NO

REPLACE WITH CORRECT

SIZE DEVICE.

HIGH

INSTALL BUCKING TRANSFORMER TO REDUCE LINE VOLTAGE.

1.REMOVE ALL OTHER EQUIPMENT FROM ICEMAKER CIRCUIT

2.INSTALL NEW DEDICATED CIRCUIT FOR ICEMAKER.

IS

OTHER EQUIP.

YES ON SAME

CIRCUIT

NO

1.CHECK FOR LOOSE OR CORRODED CONNECTION IN SUPPLY WIRING.

2.CHECK SUPPLY WIRING FOR UNDER- SIZED WIRE, AND REPLACE.

3.INSTALL BOOSTING TRANSFORMER TO RAISE LINE VOLTAGE.

23

90846

Image 27
Contents From kent M O R a N D U MSpiral ICEMAKER-DISPENSER Table of Contents Table of Contents cont’d Important Installation Notice Safety PrecautionsUnpacking DescriptionInstallation LocationPlumbing Beverage System InstallationMounting Template Model SID650--80 15 7/8 29/32 29 1/4 18 3/413/16 28 3/4 14 7/8 15 3/4 17 5/8 29 1/4 34 3/8 34 7/8 16 5/816 1/4 11 1/8Models Post MIX Beverage Syustem Schematic BC Models Post MIX Beverage System Schematic Icemaker Start UPCam Time Switch Action Operating InstructionsIcemaker Operating Instructions Wiring Schematic 115 / 1 / 60 HZ Wiring Diagram Refrigeration Schematic Cleaning Instructions MaintenanceDispenser Section For Units with Beverage SystemBeverage System Clearing Evaporator FREEZE-UP MAINTENANCE/ADJUSTMENT ProcedureThermostat Altitude Adjustments ICE Thickness AdjustmentCleaning / Replacing the Filter Cleaning the Condenser AIR-COOLED UnitHarvest Timer Adjustment Manual Filling Detail of CAM Wheel # T1 Troubleshooting Guide 90846 90846 RUN? GO to Is ICE Production Icemaker Inoperative YES RUN RUN/STOP Check Voltage Problems No ICE on Evaporator Harvest YES ±10%? CON’T Check Refrigeration System 90846 Dispenser Problem YES Does Agitator ROTATE? 90846 Parts List Electrical ControlsRefrigeration Components Description Refrigeration Components cont’d Evaporator ComponentsMiscellaneous Components Warranty IMI Cornelius INC