A.“Manually”adjust the cam tabs by using each “click”as the cam tab is rotated as equivalent to .75 se- conds.
B.Set up cam wheel #1 with the left and right cam tabs
C.Adjust the cam tabs on wheels #2 through #5 in sequence as shown in the chart. Rotate the cam wheels manually downward to set each wheel.
D.After the cam tabs are manually set, reconnect power to the ice maker.
E.Rotate the cam wheels slightly to activate the timer motor (#1
F.Using stopwatch, time the cam switch
MANUAL FILLING
In the event that the icemaker is not functioning, the hopper may be manually filled with ice.
1.Open the hinged service door on the upper left aide panel.
2.Put the “Stop/Run”switch in the “Stop”position.
WARNING: Electrical power is on to the agitator motor and gate solenoid. Avoid contact with these components.
3.Remove the ice drop and ice storage hopper cover.
4.Fill hopper with ice and replace covers. The unit is now ready for dispensing.
CAUTION: Do not use crushed of flaked ice.
Use of bagged ice, which has frozen into large chunks can void warranty. The agitator is not designed to be and ice crusher. Use of large chunks of ice which “jam up” inside the
hopper will cause failure of the agitator motor and damage the hopper. If bagged ice is used it must be carefully and completely broken into small,
19 | 90846 |