Miele DA403 installation instructions Reprogramming the charcoal filter timer

Page 16

Operation

Reprogramming the charcoal filter timer

The active charcoal filter can only be used in recirculation mode and cannot be used to exhaust fumes.

The charcoal filter timer is not preset.

Before using the hood in recirculation mode, the charcoal filter timer must be programmed.

^Turn off the fan using the On/Off button.

The lit indicator shows the programmed time:

1st indicator from the left

=

20 hours

2nd indicator from the left

=

30 hours

3rd indicator from the left

=

40 hours

4th indicator from the left

=

50 hours

^Use the "/+" button to select the desired time.

^Store the selection by pressing the charcoal filter button.

^Press the Delayed Shut Down and charcoal filter buttons at the same time.

The indicator for the charcoal filter and one of the "/+" indicators will flash.

If the procedure is not stored within 4 minutes of programming, the hood will automatically default to the "old" data.

16

Image 16
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkFunctional description Recirculation modeAir extraction Guide to the appliance On/Off button Fan power selection Delayed shut downChimney extension Canopy Grease filter Charcoal filter Grease filter buttonSelecting the power level Intensive settingAutomatically switching back the Intensive power level OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingFilter timers Checking the filter timersGrease filters Charcoal filterReprogramming the timers Reprogramming the grease filter timerReprogramming the charcoal filter timer Cleaning and Care Cleaning the casingStainless steel ControlsCleaning the grease filter Grease filtersActive charcoal filter Changing the light bulb Repairs After Sales ServiceMieleCare Page Installation Instructions Structural support Electrical data This Appliance Must be GroundedAppliance dimensions Appliance dimensions Installation Installation accessoriesInstallation instructions Screws 8 x 60 mm with WashersAir extraction Exhaust ducting and connectionsCondensate trap Disposal of packing material Caring for the environmentDisposal of an old appliance Alteration rights reserved