Miele DA403 installation instructions Air extraction, Exhaust ducting and connections

Page 29

Air extraction

Danger of toxic fumes.

Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. The exhaust gases extracted by the hood should be vented outside of the building only.

Do not terminate the exhaust ducts in attics, garages, crawlspaces, etc.

Please read and follow the "Important Safety Instructions" to reduce the risk of personal injury. Follow all local building codes when installing the hood.

Exhaust ducting and connections

The ducting should be as short and straight as possible, and the number of sharp bends should be minimized.

For most efficient air extraction, the diameter of the ductwork should not be less than 6" (150 mm). Use of flat ducts also reduces the air extraction efficiency.

Noise levels of the hood will increase if flat or round ducts of less than 6" (150 mm) in diameter are used.

,WARNING

To reduce the risk of fire only use metal ductwork.

CAUTION

To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

Use smooth or flexible pipes made from approved non-flammable materials for exhaust ducting.

Where the ductwork is horizontal, it

must slope away from the hood at least 1/8" per foot (1 cm per meter) to prevent condensation dripping into the appliance.

If the exhaust is ducted through an outside wall, a Miele Telescopic Wall Vent can be used.

29

Image 29
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Only if Evacuate and Call the Fire DepartmentTo reduce the risk of fire only use metal ductwork InstallationAir extraction Recirculation modeFunctional description Guide to the appliance Delayed shut down On/Off button Fan power selectionChimney extension Canopy Grease filter Charcoal filter Grease filter buttonIntensive setting Selecting the power levelAutomatically switching back the Intensive power level OperationFan performance Turning off the fan Automatic Safety Shut OffDimming the lighting Turning the lighting on/offChecking the filter timers Filter timersGrease filters Charcoal filterReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Cleaning the casing Cleaning and CareStainless steel ControlsGrease filters Cleaning the grease filterActive charcoal filter Changing the light bulb MieleCare After Sales ServiceRepairs Page Installation Instructions Structural support This Appliance Must be Grounded Electrical dataAppliance dimensions Appliance dimensions Installation accessories InstallationInstallation instructions Screws 8 x 60 mm with WashersExhaust ducting and connections Air extractionCondensate trap Disposal of an old appliance Caring for the environmentDisposal of packing material Alteration rights reserved