Miele DA403 installation instructions Condensate trap

Page 30

Air extraction

If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue.

Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork.

Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.

Important!

If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be insulated to reduce condensation.

Condensate trap

optional accessory

In some cases, a condensate trap may also be required to collect and evaporate any condensate which may occur. This optional accessory is available for ducts 5" (125 mm) and

5 7/8" (150 mm) in diameter.

When installing a condensate trap, ensure that it is positioned vertically and if possible directly above the exhaust outlet. The arrow on the casing shows the venting direction.

30

Image 30
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkRecirculation mode Functional descriptionAir extraction Guide to the appliance Chimney extension Canopy Grease filter Charcoal filter On/Off button Fan power selectionDelayed shut down Grease filter buttonAutomatically switching back the Intensive power level Selecting the power levelIntensive setting OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingGrease filters Filter timersChecking the filter timers Charcoal filterReprogramming the timers Reprogramming the grease filter timerReprogramming the charcoal filter timer Stainless steel Cleaning and CareCleaning the casing ControlsCleaning the grease filter Grease filtersActive charcoal filter Changing the light bulb After Sales Service RepairsMieleCare Page Installation Instructions Structural support Electrical data This Appliance Must be GroundedAppliance dimensions Appliance dimensions Installation instructions InstallationInstallation accessories Screws 8 x 60 mm with WashersAir extraction Exhaust ducting and connectionsCondensate trap Caring for the environment Disposal of packing materialDisposal of an old appliance Alteration rights reserved