Miele DA403 Installation, To reduce the risk of fire only use metal ductwork

Page 6

IMPORTANT SAFETY INSTRUCTIONS

Installation

,WARNING

To reduce the risk of fire only use metal ductwork.

Provided a larger distance is not given by the manufacturer of the

cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood:

22" (550 mm) above electric cooktops,

30" (762 mm) above gas cooktops,

26" (650 mm) above an open electric grill or an open electric boiler/fryer.

If local building codes require a greater safety distance, follow their requirement.

If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance.

Be careful not to damage hidden electrical wiring or plumbing when

cutting or drilling into the wall or ceiling.

Do not use an extension cord to connect the appliance to electricity.

Extension cords do not guarantee the required safety of the appliance, (e.g. danger of overheating).

Do not install this hood over cooktops burning solid fuel.

Any fittings, sealant, or materials used to install the ductwork must be made of approved non-flammable

materials.

Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room ventilating ductwork. Seek professional advice before connecting

an exhaust hood vent to an existing, inactive chimney or vent flue.

Ducted fans must always be vented outdoors.

Make sure that the airflow in the room is sufficient for combustion

and exhausting of all non-electric heating appliances (water heaters, gas cooktops, gas ovens, etc.), otherwise backdrafts may occur. Follow the heating manufacturer’s guidelines and safety standards or those published by the National Fire Protection Association (NFPA) or the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE).

If in doubt, consult an experienced professional.

6

Image 6
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkRecirculation mode Functional descriptionAir extraction Guide to the appliance Chimney extension Canopy Grease filter Charcoal filter On/Off button Fan power selectionDelayed shut down Grease filter buttonAutomatically switching back the Intensive power level Selecting the power levelIntensive setting OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingGrease filters Filter timersChecking the filter timers Charcoal filterReprogramming the timers Reprogramming the grease filter timerReprogramming the charcoal filter timer Stainless steel Cleaning and CareCleaning the casing ControlsCleaning the grease filter Grease filtersActive charcoal filter Changing the light bulb After Sales Service RepairsMieleCare Page Installation Instructions Structural support Electrical data This Appliance Must be GroundedAppliance dimensions Appliance dimensions Installation instructions InstallationInstallation accessories Screws 8 x 60 mm with WashersAir extraction Exhaust ducting and connectionsCondensate trap Caring for the environment Disposal of packing materialDisposal of an old appliance Alteration rights reserved