Miele DA403 installation instructions Functional description, Air extraction, Recirculation mode

Page 7

Functional description

The hood offers two modes of operation:

Air extraction

The air is drawn in and cleaned by the grease filters and directed outside.

The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur. When the hood is turned on, the air pressure of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside.

Recirculation mode

Air is drawn through the grease filters and an active charcoal filter. The filtered air is then recirculated back into the kitchen through a vent at the top of the hood’s chimney.

The recirculation mode requires an install kit and charcoal filter which are optional accessories.

Before using the hood in recirculation mode, ensure that the active charcoal filter is in place, see "Cleaning and care".

7

Image 7
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Only if Evacuate and Call the Fire DepartmentTo reduce the risk of fire only use metal ductwork InstallationFunctional description Recirculation modeAir extraction Guide to the appliance Grease filter button On/Off button Fan power selectionDelayed shut down Chimney extension Canopy Grease filter Charcoal filterOperation Selecting the power levelIntensive setting Automatically switching back the Intensive power levelFan performance Turning off the fan Automatic Safety Shut OffDimming the lighting Turning the lighting on/offCharcoal filter Filter timersChecking the filter timers Grease filtersReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Controls Cleaning and CareCleaning the casing Stainless steelGrease filters Cleaning the grease filterActive charcoal filter Changing the light bulb Repairs After Sales ServiceMieleCare Page Installation Instructions Structural support This Appliance Must be Grounded Electrical dataAppliance dimensions Appliance dimensions Screws 8 x 60 mm with Washers InstallationInstallation accessories Installation instructionsExhaust ducting and connections Air extractionCondensate trap Disposal of packing material Caring for the environmentDisposal of an old appliance Alteration rights reserved