Franke Consumer Products FGL 9015 XS manual Recommendations and Suggestions, Installation, Use

Page 3

RECOMMENDATIONS AND SUGGESTIONS

The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance.

INSTALLATION

The manufacturer will not be held liable for any damages resulting from in- correct or improper installation.

The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please re- fer to the paragraphs on working dimensions and installation).

Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.

For Class I appliances, check that the domestic power supply guarantees adequate earthing.

Connect the extractor to the exhaust flue through a pipe of minimum diame- ter 120 mm. The route of the flue must be as short as possible.

Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).

If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.

USE

The extractor hood has been designed exclusively for domestic use to elimi- nate kitchen smells.

Never use the hood for purposes other than for which it has been designed.

Never leave high naked flames under the hood when it is in operation.

Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.

Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.

Do not flambè under the range hood; risk of fire

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concern- ing use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appli- ance.

MAINTENANCE

Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.

Clean and/or replace the Filters after the specified time period (Fire hazard).

Clean the hood using a damp cloth and a neutral liquid detergent.

The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

650 mm min.

EN

 

3

 

3

Image 3
Contents Instructions for use and installation Inhaltsverzeichnis IndexIndice SommaireUSE InstallationMaintenance Recommendations and SuggestionsCharacteristics DimensionsComponents Wall drilling and bracket fixing InstallationRecirculation Version AIR Outlet Mounting the hood bodyConnections Ducted Version AIR Exhaust SystemLower exhaust flue Flue assemblyElectrical Connection Upper exhaust flueControl panel USELighting MaintenanceGrease filters Activated charcoal filter Recirculation versionManutenzione InstallazioneConsigli E Suggerimenti USOCaratteristiche IngombroComponenti Foratura Parete e Fissaggio Staffe InstallazioneUscita Aria Versione Filtrante Montaggio Corpo CappaConnessioni Uscita Aria Versione AspiranteCamino inferiore Montaggio CaminoConnessione Elettrica Camino superioreQuadro comandi USOIlluminazione ManutenzioneFiltri antigrasso Filtro antiodore Versione FiltranteConseils ET Suggestions UtilisationEntretien Caracteristiques EncombrementComposants Perçage Paroi et Fixation Brides Sortie AIR Version Filtrante Montage Corps HotteBranchements Sortie AIR Version AspiranteCheminée inférieure Montage CheminéeBranchement Electrique Cheminée supérieureUtilisation Tableau des commandesEclairage EntretienFiltres anti-graisse Filtre anti-odeur Version filtranteWartung Empfehlungen UND HinweiseMontage BedienungCharakteristiken PlatzbedarfKomponenten Montage Montage des Haubenkörpers Anschluss der AbluftversionAnschluss der Umluftversion Unterer Kaminteil ElektroanschlussKaminmontage Oberer KaminteilSchalttafel BedienungBeleuchtung WartungFettfilter Geruchsfilter UmluftversionKullanim Tavsiyeler VE ÖnerilerÖzellikler BoyutlarParçalar Duvarın Delinmesi ve Braketlerin Sabitlenmesi MontajDavlumbaz Gövdesi Montajı BağlantılarAspİratörlü Model Hava Çikişi Alt baca Bacanın montajıElektrİk Bağlantisi Üst bacaKumanda Tablosu KullanimAydınlatma BakimYağ tutucu filtreler Koku Filtresi Filtreli ModelPage Page 436004820ver1

FGL 6015 XS, FGL 7015 XS, FGL 9015 XS specifications

Franke Consumer Products has solidified its reputation in the kitchen appliance market through its innovative and high-quality kitchen sinks. Among their standout offerings are the FGL 6015 XS, FGL 9015 XS, and FGL 7015 XS models. Each of these products brings a unique combination of functionality, design, and durability tailored to meet the diverse needs of modern kitchens.

Starting with the FGL 6015 XS, this sink is designed with both aesthetic appeal and practicality in mind. With its sleek lines and modern finish, it complements a variety of kitchen styles. The sink is made from Franke's proprietary Fragranite material, which is a blend of acrylic and granite. This unique composition not only gives it a visually striking appearance but also enhances its durability. The FGL 6015 XS is resistant to scratches, stains, and heat, making it an ideal choice for busy kitchens. Additionally, it features an undermount installation that provides seamless integration with countertops, creating a clean and elegant look.

Next, the FGL 9015 XS stands out for its spacious design, perfect for multitasking in the kitchen. This model boasts a large single bowl that provides ample space for washing dishes or preparing food. Like the FGL 6015 XS, the FGL 9015 XS is crafted from Fragranite, ensuring longevity and resistance to everyday wear and tear. This sink is easy to clean and maintain, with a non-porous surface that inhibits bacterial growth. Furthermore, the FGL 9015 XS features a modern, angular design that adds a touch of sophistication to any kitchen decor.

Lastly, the FGL 7015 XS combines versatility with functionality, making it suitable for both small and large kitchens. This sink offers a dual-bowl configuration, allowing users to wash and rinse simultaneously. Its durable Fragranite construction ensures that it can withstand the rigors of daily use, all while maintaining its elegance. The FGL 7015 XS also includes soundproofing features that minimize noise when washing dishes, making for a quieter kitchen environment.

All three models showcase Franke's commitment to quality and innovation, making them excellent choices for homeowners looking to enhance their kitchens with durable, stylish, and functional sinks. With features like easy maintenance, resistance to scratches and stains, and a variety of stylish designs, the FGL 6015 XS, FGL 9015 XS, and FGL 7015 XS cater to the needs of modern cooking lifestyles while adding a touch of elegance to any kitchen space.