Installation and service must be performed by a qualified installer, service agency or gas supplier.

In Massachusetts a licensed plumber / gas fitter is required.

This appliance must be installed with its own shut off valve and the included gas pressure regulator. Both the valve and the regulator must be easily accessible to the consumer to turn on or shut off the gas supply after the appliance is installed.

This appliance and its individual shut off valve must be disconnected from the gas supply during any pressure testing of that system performed in excess of ½ psi

(3.5 kPa). The appliance must be isolated from the gas supply line by closing its individual manual shut off valve at test pressures equal to or less than ½ psi (3.5 kPa).

Any pipe connections must be made using a thread sealant approved for gas connections. Failure to correctly install these items could lead to a gas leak and subsequent explosion.

The gas connection must be made in accordance with local codes or, in the absence of local codes, with

-the National Fuel Gas Code, ANSI Z 21.1 / NFPA 54

for the USA

or

-the current Can / CGA B 149.1 and .2 Installation Codes for gas burning appliances for Canada.

Make sure that the maximum gas supply pressure before the gas pressure regulator is never more than ½ psi for both natural gas or LP gas.

The minimum required gas pressure to get the required gas input is

4" w.c. for natural gas 10" w.c. for LP gas.

30

Image 30
Contents Operating Instructions Gas Cooktop What to do if YOU Smell GAS Contents Important Safety Instructions Installation and connectionCorrect usage Protection from damagePersonal safety Further safety notes Damage to the applianceGuide to the cooktop Wok burner Before using the cooktop Cleaning the cooktopUsing the cooktop Fast-Ignition-SystemTurning on and off / Regulating Turning on Turning offRegulating the wok burner Pan size Suitable pansWok burners Safety feature Using the cooktop during a power failureCleaning and care Grates, Control KnobsCeramic surface Dismantling and cleaning BurnerReassembling Auxiliary, Normal and Fast burner Reassembling the wok burner Flame goes out after being lit Frequently asked questionsBurners do not ignite after several attempts Possible fault Igniters no longer workTechnical Service MieleCareInstallation Instructions Installation Recommended Not recommended Not allowedSafety distances above the appliance Appliance dimensions Installation Setting the cooktop into place Securing the cooktopSealing Power supply Electrical connectionWiring diagram Gas connection Gas pressure regulator Nominal Rating Table Converting to another type of gas Help protect our environment Disposal of packing materialsDisposal of an old appliance Page Alterations rights reserved