Miele KM391 operating instructions Gas pressure regulator

Page 31

Gas connection

Gas pressure regulator

A pressure regulator that is convertible from natural to LP gas (Propane) or vice versa is included with the appliance.

The included regulator corresponds with the gas type of the cooktop. Verify before installing.

The adjusted pressure is: natural gas - 4" w.c.

LP gas - 10" w.c.

aCooktop

b½" NPT

cRegulator

As shown in the above diagram, the included regulator must be used when connecting the Miele cooktop to your gas supply. This item has been customized by Miele to meet all applicable safety requirements. Make sure the regulator is easily accessible for adjustment after the appliance has been installed.

For convenience, an AGA or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas connection and the regulator. This will allow the appliance to be lifted out of the countertop for cleaning or servicing. Make sure that any drawers, cabinet doors, etc., do not rub on this gas hose.

Do not use any regulator unless it has been supplied by Miele. Doing so may cause a gas leak.

If there is any doubt concerning installation contact the Miele Technical Service Department:

U1-800-999-1360 techserv@mieleusa.com

V1-800-565-6435 service@miele.ca

After connecting the appliance check all fittings for gas leaks e.g. with soapy water.

When installed properly, the flame will be steady and quiet. It will also have a sharp, blue inner core that will vary in length proportional to the burner size.

Flame adjustment will not be necessary.

31

Image 31
Contents Operating Instructions Gas Cooktop What to do if YOU Smell GAS Contents Installation and connection Important Safety InstructionsProtection from damage Correct usagePersonal safety Damage to the appliance Further safety notesGuide to the cooktop Wok burner Cleaning the cooktop Before using the cooktopFast-Ignition-System Using the cooktopTurning on and off / Regulating Turning off Turning onRegulating the wok burner Suitable pans Pan sizeWok burners Using the cooktop during a power failure Safety featureGrates, Control Knobs Cleaning and careCeramic surface Burner Dismantling and cleaningReassembling Auxiliary, Normal and Fast burner Reassembling the wok burner Igniters no longer work Frequently asked questionsBurners do not ignite after several attempts Possible fault Flame goes out after being litMieleCare Technical ServiceInstallation Instructions Recommended Not recommended Not allowed InstallationSafety distances above the appliance Appliance dimensions Installation Securing the cooktop Setting the cooktop into placeSealing Electrical connection Power supplyWiring diagram Gas connection Gas pressure regulator Nominal Rating Table Converting to another type of gas Disposal of packing materials Help protect our environmentDisposal of an old appliance Page Alterations rights reserved