CU1526, CU2026, CU3030
User Manual
Cleaning, Sanitation and Maintenance
This ice system requires three types of maintenance:
•Remove the build up of mineral scale from the ice machine’s water system and sensors.
•Sanitize the ice machine’s water system and the ice storage bin.
•Clean or replace the air filter and clean the air cooled condenser (air cooled models only).
It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition. Without human intervention, sanitation will not be maintained. Ice machines also require occasional cleaning of their water systems with a specifically designed chemical. This chemical dissolves mineral build up that forms during the ice making process.
Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine is cleaned and sanitized.
The ice machine’s water system should be cleaned and sanitized a minimum of twice per year.
Note: The front On/Off switch must be in the ON position during the scale removal and sanitation process.
1.Remove the left front louvered panel.
2.Remove the top panel.
3.If the machine is operating, push and release the Harvest button. When the machine completes the Harvest cycle it will stop. If the bin is full (b shows in display) push and release the Off button.
4.Remove all ice from the storage bin
5.Push and release the Clean button. The yellow Clean light will blink and the display will show C. The machine will drain the reservoir and refill it. Go onto the next step when the reservoir has filled.
Ice machine scale remover contains acids. Acids can cause burns.
If concentrated cleaner comes in contact with skin, flush with water. If swallowed, do NOT induce vomiting. Give large amounts of water or milk. Call Physician immediately. Keep out of the reach of children.
7.Allow the ice machine scale remover to circulate in the water system for at least 10 minutes.
8.Push and release the Clean button again. The yellow Clean light will be on continuously and the machine will drain and refill the reservoir repeatedly to purge out the ice machine scale remover and residue.
9.Allow the drain and refill process to continue for at least 20 minutes.
10.Push and release the Off button. The clean cycle will stop and the display will show O.
Note: If unit has not been
11.Mix a cleaning solution of 1 oz of ice machine scale remover to 12 ounces of water.
12.Locate curtain, push in on edge of curtain by pivot pin to release it. Pull curtain out of machine.
13.Remove water distributor from ice machine. Inspect distributor for restricted orifice holes. Be sure all holes are fully open.
6.Pour 8 ounces of Scotsman Clear 1 ice machine scale remover into the reservoir.
May 2008