Installation: Product Specifications
Location Limitations:
The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room. Water cooled models discharge warm water into the building’s drain. Space needs to be provided for service access.
Space Limitations
Do not block air flow at the front.
In most cases, CU3030 air cooled models installed without legs or casters will experience reduced ice making capacity.
Environmental Limitations
| Minimum | Maximum |
Air temperature | 50oF. | 100oF. |
Water temperature | 40oF. | 100oF. |
Water pressure | 20 psi | 80 psi |
|
|
|
Note: Ice making capacity will be severely reduced for air cooled machines in hot environments, such as those over 95 degrees.
Power supply – acceptable voltage ranges
| Minimum | Maximum |
115 volt model | 104 | 126 |
230 volt model | 198 | 253 |
Warranty Information
Warm Air Out
Room Temp Air In
Air Flow - Do Not Restrict
Airflow for air cooled models is in the front left and out the front right; CU3030 air cooled models also take air in from the bottom of the cabinet
Built In Situations:
•If built in under the counter with no space above, the bin cannot be removed without moving the unit.
•If built in with 1" or more clearance above the unit, the bin can be removed without moving the unit.
•If built in with between 1/2 and 1 inch of clearance, releasing the top panel's back flap prior to placement will allow removal of the bin without moving the unit.
The warranty statement for this product is provided separately from this manual. Refer to it for applicable coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance, corrections to installations, or situations when the machine is operated in circumstances that exceed the limitations printed above.
Product Information
The product is a self contained cuber with bin. That type of machine is designed to be free standing or it can be built in under the counter.
Options
Casters may be used in place of the supplied legs, the kit number is KBC1.
When not using legs or casters, most codes require sealing to the floor. Kit numbers to allow sealing are KPUFM26 and KPUFM30.
May 2008